INSTALLATION

22

CONNECTION IN DUCTING VERSION

When installing the ducting version, connect the

hood to the chimney using either a flexible or rigid

pipe ø 150 or 120 mm, the choice of which is left

to the installer.

To install a ø 150

• To install the dumper

10.

• Fix the pipe in position using sufficient pipe clamps

(not supplied).

To install a ø 120

• To install a ø 120 mm air exhaust connection, insert

the reducer flange

9 on the dumper 10.

• Fix the pipe in position using sufficient pipe clamps

(not supplied).

• Remove any activated charcoal filters.

CONNECTION IN RECYCLING VERSION

• Insert the Connector extensions 14.1 into the side of

the Connector 15.

• Insert the Connector 15 into the Support bracket 7.3

and fix it with the screws.

• Fasten the Support bracket 7.3, fixing it to the upper

part with the Screws.

• Make sure that the Connector extensions outlet

14.1 is in correspondence with the Chimney open-

ings both horizontally and vertically.

• Join the Connector 15 to the Hood canopy outlet

using a rigid or flexible pipe ø¸150 mm, selection of

which is at the discretion of the installation techni-

cian.

• Make sure that the Activated charcoal odour filter

has been fitted.

�����

��

��

��

�����

��

���

���

���

���

��

����