Dexter Laundry T-900 (30-Cycle) User Manual
Page 6

6
ELECTRICAL
╔════════════════════════════════════════════════════════════════════╗
║ WARNING ║
║ SHUT OFF POWER AND WATER BEFORE OPENING ANY SERVICE PANELS. ║
╚════════════════════════════════════════════════════════════════════╝
Dexter T900/T950 washing machines are intended to be permanently installed
appliances. The machine should be connected to an individual branch circuit not
shared by lighting or other equipment. The connection should be sheathed in
liquid-tight flexible conduit, or equivalent, with conductors of the proper size
and insulation. No power cord is provided. Such connections should be made by
a qualified electrician, in accordance with the wiring diagram. (Suggest
minimum wire size of 12 ga.)
FUSING REQUIREMENTS
15 Amp Time Delay (Dual Element) Fuse(s) (or equivalent circuit breaker).
TO MAKE ELECTRICAL CONNECTIONS:
Remove screw and lift out cover located on upper left of machine (viewed from
back).
Figure 3 - Electrical Power Connections
If power is 208-240-3PH-60HZ
connect L1, L2, L3 and ground.
(If there is a high phase it
must be connected to L3.)
If power is 208-240-1PH-60HZ
connect L1, L2 and ground.
IMPORTANT
FOR SAFETY AND PROPER EQUIPMENT
OPERATION THE GROUND LUG MUST
BE CONNECTED TO A GOOD EXTERNAL
GROUND.