RAPID ADVANCE MODE

To enter the Rapid Advance mode, insert the key into the Rapid

Advance/Run/Program lock and turn the key counter-clockwise (CCW). The

Rapid Advance mode must be entered during the cycle. If the cycle has not

yet started, press the “DOWN” button or the “UP” button to choose a cycle

and then the “START” button to begin the cycle.

To advance to the next step in the cycle, push both the “UP” and “START”

buttons at the same time. The display will show “Ad” (advance).

If advancing during a bath, all water valves will turn off and the drain

will open until the “open drain” step is completed. The cycle will then

continue to the next bath or to the spin of the current bath if the

programming includes spin time.

If advancing during a chemical injection of a bath or after a chemical

injection of the bath but before the low water level is reached, the

injector will turn off and the hot and the cold water valves to the tub will

turn on until the low water level is reached or for 30 seconds, whichever

comes first. Then the drain will open and proceed to the next step after

the “open drain” step is completed.

If advancing before a chemical injection of the bath, the drain will open

immediately and the cycle will proceed to the next step when the “open

drain” step is completed.

If advancing during a spin, the tumbler will begin to decelerate

immediately. However the cycle may proceed to the next bath before the

tumbler comes to a complete stop. The cycle cannot be advanced further

while the tumbler is decelerating.

If a temperature PCB is installed in the I/O PCB and the temperature

programmed from 20 to 90 (Celsius), advancing will turn off the heater relay

or steam valve immediately, if either is on, and open the drain after a

three second delay. If the display shows a water temperature from 65 to 90

(may be displayed by pressing the “DOWN” and “START” buttons together), the

drain will close again when the washer indicates empty and the hot and the

cold water valves to the tub will turn on until the low water level is

reached. The cycle will then continue to the next bath, or if programmed, to

the spin of the current bath.

To exit the Rapid Advance mode during the cycle, turn the key to Run. The

cycle will continue normally.

Notes:

• The cycle cannot be advanced during the “open drain” step of the bathes.
• The cycle cannot be advanced when the hot and cold water valves to the

tub are on after advancing during or after a chemical injection.

• The cycle cannot be advanced again while the hot and cold water valves to

the tub are on after advancing when the water temperature was 65 to 90.

• The Rapid Advance mode may only be entered after a cycle is started.
• The indicator lights will show to which segment the cycle has been

advanced.