Dexter Laundry T-900 (30-Cycle) User Manual
Page 13

13
FIGURE 9 - BATH SETTING LIMITS
Settings for
each bath
Setting Limits
Description
Cycle Time
0 to 30 minutes
(1 min. increments)
The Cycle time (tumble) settings are 0 min. to 30 min. in 1 min. increments for each bath. If
the setting is 0, then that bath is skipped over. For the Final Rinse /Extract bath, the
minimum time must be 1 min.
Water
Temp.
HOT, WARM,
COLD and NO
WATER
The water temperature setting is displayed as HH = hot, CH = warm, CC = cold and EE = No
water bath. When the No Water bath is selected, the water level can be set to either high or low
and NO Injection will be made even if the injection source is programmed.
Water
Level
HIGH or LOW
The water level setting is displayed as HI for High level and LO for low level.
Injection
Source
0 to 6
The injection source settings are 0 through 6 with 0 being no injection and settings 1 through
6 relating to an injection source. See Recommended Injection Table.
Spin Time
0 to 10 minutes
(1 min. increments)
The spin time settings are 0 min. to 10 min. in 1 min. increments. If the setting is 0, there
is no spin for the bath. Final Rinse/Extract minimum setting is 1 min.