beautypg.com

Dexter Laundry T-900 (30-Cycle) User Manual

Page 13

background image

13

FIGURE 9 - BATH SETTING LIMITS


Settings for

each bath


Setting Limits


Description


Cycle Time


0 to 30 minutes

(1 min. increments)


The Cycle time (tumble) settings are 0 min. to 30 min. in 1 min. increments for each bath. If

the setting is 0, then that bath is skipped over. For the Final Rinse /Extract bath, the

minimum time must be 1 min.


Water

Temp.


HOT, WARM,

COLD and NO

WATER


The water temperature setting is displayed as HH = hot, CH = warm, CC = cold and EE = No

water bath. When the No Water bath is selected, the water level can be set to either high or low

and NO Injection will be made even if the injection source is programmed.


Water

Level


HIGH or LOW


The water level setting is displayed as HI for High level and LO for low level.


Injection

Source


0 to 6


The injection source settings are 0 through 6 with 0 being no injection and settings 1 through

6 relating to an injection source. See Recommended Injection Table.


Spin Time


0 to 10 minutes

(1 min. increments)


The spin time settings are 0 min. to 10 min. in 1 min. increments. If the setting is 0, there

is no spin for the bath. Final Rinse/Extract minimum setting is 1 min.