Dexter Laundry T-900 (30-Cycle) User Manual

Page 18

background image

18

Step 4 - Close the drain valve.

Step 5 - Turn on the cold water to the tub.

The pressure switch low level setting can be tested at this point.

The drain valve is closed and cold water is on for as long as the

START button is pushed. When the water level reaches a low level,

the water valve will turn off and no additional cold water can be

added. (The time required to reach a low water is dependent on input

water pressure. It may require several minutes.)

Step 6 - Turn on the cold water to the dispenser.

The pressure switch low level setting can also be tested with this

step. For details see Step 5.

Step 7 - Turn on the hot water to the tub.

The pressure switch high level setting of the pressure switch can be

tested at this point. The drain valve is closed and hot water on for

as long as the START button is pushed. When the water level reaches

a high level, the water valve will turn off and no additional hot

water can be added. (The time required to reach a high water is

dependent on input water pressure. It may require several minutes.)

Step 8 - Turn on the hot water to the dispenser.

The pressure switch high level setting can also be tested with this

step. For details see Step 7.

Step 9 - Forward tumble.

Step 10 - Reverse tumble.

Step 11 - Open drain.

Step 12 - Intermediate spin.

The I/O interface outputs labeled Reverse and Speed1 will be active

(the two RED LED’s will light).

Step 13 - Full speed spin.

The I/O interface outputs labeled Reverse, Speed1 and Speed2 will be

active (the three RED LED’s will light).

DO NOT USE STEP 14 IF YOU HAVE CUSTOMIZED CYCLES PROGRAMMED AS
THIS WILL SET THE CYCLES BACK TO THE FACTORY PRESETS.

Step 14 - Preset Cycles. Push START and hold, then push SCROLL UP. This

will reset the DEXTER preset cycles back to the factory settings.

At cycle complete, switch the Advance/Run/Program switch to the Run position

and the unit is ready to select a run cycle.