Dexter Laundry T-900 (30-Cycle) User Manual
Page 18

18
•
Step 4 - Close the drain valve.
•
Step 5 - Turn on the cold water to the tub.
The pressure switch low level setting can be tested at this point.
The drain valve is closed and cold water is on for as long as the
START button is pushed. When the water level reaches a low level,
the water valve will turn off and no additional cold water can be
added. (The time required to reach a low water is dependent on input
water pressure. It may require several minutes.)
•
Step 6 - Turn on the cold water to the dispenser.
The pressure switch low level setting can also be tested with this
step. For details see Step 5.
•
Step 7 - Turn on the hot water to the tub.
The pressure switch high level setting of the pressure switch can be
tested at this point. The drain valve is closed and hot water on for
as long as the START button is pushed. When the water level reaches
a high level, the water valve will turn off and no additional hot
water can be added. (The time required to reach a high water is
dependent on input water pressure. It may require several minutes.)
•
Step 8 - Turn on the hot water to the dispenser.
The pressure switch high level setting can also be tested with this
step. For details see Step 7.
•
Step 9 - Forward tumble.
•
Step 10 - Reverse tumble.
•
Step 11 - Open drain.
•
Step 12 - Intermediate spin.
The I/O interface outputs labeled Reverse and Speed1 will be active
(the two RED LED’s will light).
•
Step 13 - Full speed spin.
The I/O interface outputs labeled Reverse, Speed1 and Speed2 will be
active (the three RED LED’s will light).
DO NOT USE STEP 14 IF YOU HAVE CUSTOMIZED CYCLES PROGRAMMED AS
THIS WILL SET THE CYCLES BACK TO THE FACTORY PRESETS.
•
Step 14 - Preset Cycles. Push START and hold, then push SCROLL UP. This
will reset the DEXTER preset cycles back to the factory settings.
At cycle complete, switch the Advance/Run/Program switch to the Run position
and the unit is ready to select a run cycle.