beautypg.com

Connecting the 1046 to your system, Operating controls, Quad compressor/ limiter – dbx 1046 User Manual

Page 7: Front panel, Channel one, Channel two, Channel three, Channel four

background image

3

Connecting the 1046 to your system

To connect the 1046 to your system, refer to the following steps:

• Turn off all equipment before making any connections.

• Mount the 1046 in a rack

Install the 1046 in a rack with the rack screws provided. It can be mounted above or below anything

that does not generate excessive heat. Ambient temperatures should not exceed 113˚ F (45˚ C) when
equipment is in use. Although the unit is shielded against radio frequency and electromagnetic
interference, extremely high fields of RF and EMI should be avoided.

• Make audio connections via XLR, 1/4” TRS, or 1/4” TS plugs.

Both types of connectors for the inputs and outputs can be used for balanced or unbalanced

connections. The use of more than one connector at a time for the input/output pair could unbalance
balanced lines, cause phase cancellations, short a conductor to ground, or cause damage to other
equipment connected to the 1046.

• Apply power to the 1046

Connect the AC power cord to the AC power receptacle on the back of the unit. Route the AC power

cord to a convenient power outlet away from audio lines. The unit may be turned on and off via the
rear panel power switch or from a master equipment power switch.

Operating Controls

Front Panel

CHANNEL ONE

INPUTS

OUTPUTS

OPERATING

LEVEL

+4 dBu

-10 dBV

CHANNEL TWO

INPUTS

OUTPUTS

OPERATING

LEVEL

+4 dBu

-10 dBV

CHANNEL THREE

INPUTS

OUTPUTS

OPERATING

LEVEL

+4 dBu

-10 dBV

CHANNEL FOUR

INPUTS

OUTPUTS

OPERATING

LEVEL

+4 dBu

-10 dBV

200-240V

50/60Hz

100-120V

50/60Hz

FUSE: REPLACE WITH SAME

TYPE FUSE AND RATING.

ATTENTION: UTILISER UN

FUSIBLE DE RECHANGE DE

MEME TYPE ET CALIBRE.

100-120V: 250mA 250V

SLOW BLOW

200-240V: T 125mA L 250V

POWER: 25 WATTS

MADE IN USA

MODEL 1046

LIMITER

COMPRESSOR

INPUT / OUTPUT LEVEL dBu

THRESHOLD

GAIN REDUCTION dB

LIMITER

COMPRESSOR

LIMITER

COMPRESSOR

LIMITER

COMPRESSOR

1046

Quad

Compressor/

Limiter

OverEasy

I/O Meter

Bypass

PROFESSIONAL PRODUCTS

OUTPUT GAIN

0

-20

-10

+10

+20

dB

RATIO

3:1

:1

8:1

4:1

1:1

1.5:1

2:1

OFF

+20

+14

+12

+4

+6

+10

dBu

THRESHOLD

-10

0

+20

+10

-40

-30

-20

dBu

INPUT / OUTPUT LEVEL dBu

THRESHOLD

GAIN REDUCTION dB

OverEasy

I/O Meter

Bypass

OUTPUT GAIN

0

-20

-10

+10

+20

dB

RATIO

3:1

:1

8:1

4:1

1:1

1.5:1

2:1

THRESHOLD

-10

0

+20

+10

-40

-30

-20

dBu

INPUT / OUTPUT LEVEL dBu

THRESHOLD

GAIN REDUCTION dB

OverEasy

I/O Meter

Bypass

OUTPUT GAIN

0

-20

-10

+10

+20

dB

RATIO

3:1

:1

8:1

4:1

1:1

1.5:1

2:1

THRESHOLD

-10

0

+20

+10

-40

-30

-20

dBu

INPUT / OUTPUT LEVEL dBu

THRESHOLD

GAIN REDUCTION dB

OverEasy

I/O Meter

Bypass

OUTPUT GAIN

0

-20

-10

+10

+20

dB

RATIO

3:1

:1

8:1

4:1

1:1

1.5:1

2:1

THRESHOLD

-10

0

+20

+10

-40

-30

-20

dBu

CHANNEL ONE

CHANNEL TWO

CHANNEL THREE

CHANNEL FOUR

PeakStopPlus

PeakStopPlus

PeakStopPlus

PeakStopPlus

Stereo

Couple

Stereo

Couple

-24 -18 -12

-6

0

+6

+12 +18

30

25

20

15

10

6

3

1

-24 -18 -12

-6

0

+6

+12 +18

30

25

20

15

10

6

3

1

-24 -18 -12

-6

0

+6

+12 +18

30

25

20

15

10

6

3

1

-24 -18 -12

-6

0

+6

+12 +18

30

25

20

15

10

6

3

1

+

+

+

+

Gain Reduction Meter - This 8 stage meter shows the amount of gain reduction due to both compression and/
or Intelligent Predictive Limiting™, displaying gain reduction from 0 to 30 dB.

Compressor Threshold Control - This control sets the level above which compression occurs, and has a 60 dB
range.

Connecting the 1046 to your system