9

Specifications

Input

Connectors:

Female XLR and 1/4” TRS (Pin 2 and tip hot)

Type:

Electronically balanced/unbalanced, RF filtered

Impedance:

Balanced > 50 kΩ, unbalanced >25 kΩ

Max Input Level:

> +24 dBu balanced or unbalanced

CMRR:

40 dB; Typically >55 dB at 1 kHz

Output

Connectors:

Male XLR and 1/4” TRS (Pin 2 and tip hot)

Type:

Servo-balanced/unbalanced, RF filtered

Impedance:

Balanced 60Ω, unbalanced 30Ω

Max Output Level:

> +21 dBu, >+20 dBm balanced/unbalanced

System Performance

Bandwidth:

20 Hz to 20 kHz, +0/-0.5 dB

Frequency Response:

0.35 Hz to 200 kHz, +0/-3 dB

Noise:

< -94 dBu, unweighted, 22 kHz measurement bandwidth

Dynamic Range:

> 118 dB, unweighted

THD+Noise:

0.009% typical at +4 dBu, 1 kHz unity gain

0.09% typical at +20 dBu, 1 kHz, unity gain

< 0.1% any amount of compression up to 40 dB, 1 kHz

IMD:

< 0.1% SMPTE

Interchannel Crosstalk:

< -85 dB, 20 Hz to 20 kHz

VCA:

dbx V2™

Stereo Coupling:

True RMS Power Summing

Compressor

Threshold Range:

-40 dBu to +20 dBu

Ratio:

1:1 to ∞:1

Threshold Characteristic:

Selectable OverEasy® or hard knee

Attack/Release Characteristic: AutoDynamic™
Attack Time:

Program-dependent, typically 15ms for 10 dB, 5 ms for 20 dB, 3 ms for 30 dB

Release Time:

Program-dependent, typically 125 dB/sec

Output Gain:

-20 to +20 dB

Limiter

Threshold Range:

+4 dBu to +22 dBu (off)

Ratio:

∞:1

Limiter Type:

PeakStopPlus™ two-stage limiter

Stage 1:

Instantaneous Transient Clamp™

Attack Time:

Zero

Release Time:

Zero

Stage 2:

Intelligent Predictive Limiting™

Attack Time:

Program-dependent, typically <5 msec

Release Time:

Program-dependent, typically 22 dB/sec

Function Switches

OverEasy®:

Activates the OverEasy® compression function.

I/O Meter:

Switches between monitoring input and output levels on the Input/Output Level meter.

Bypass:

Activates the direct input-to-output hard-wire bypass.

Operating Level (rear panel):

Switches the nominal operating level between -10 dBV and +4 dBu simultaneously for both input and output levels.

Stereo Couple:

Couples channels in stereo pairs. Channels One and Three become the master channels.

Indicators

Gain Reduction

8 segment LED bar graph at 1, 3, 6, 10, 15, 20, 25, and 30 dB

Input/Ouptut Level

8-segment LED bar graph at -24, -18, -12, -6, 0, +6, +12, and +18 dBu

Limiter Threshold:

1 LED to indicate PeakStopPlus™ limiting

Function Switches:

LED indicator for each front-panel switch

Specifications