5 troubleshooting – R&M Materials Handling ELECTRIC CHAIN HOISTS LoadMate Chain Hoist LM 10 User Manual
Page 63
LM10 I&M MANUAL/EN/11.30.2010
63/85
This document and the information contained herein, is the exclusive property of R&M Materials Handling, Inc., and represents a non-public, confidential and proprietary trade secret
that may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M Materials Handling, Inc.
Copyright © (2010) R&M Materials Handling, Inc. All rights reserved.
8.5 Troubleshooting
Table 9. Troubleshooting
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTION
Hoist does not lift or lower load
Emergency stop button is
activated
Deactivate button
Blown fuse
Replace the fuse
Motor thermal protection
activated
Allow motor to cool down
Pendant plug pin pushed out
Reinstall plug pin
Contactor terminal screws loose
Tighten screws
Mainline switch shut off
Turn switch on
Hoist does not lift load
Overload condition
Reduce load
Slip clutch worn or incorrectly
adjusted
Replace wear items or readjust
slip clutch torque
Brake not releasing
Check brake coil resistance.
Check air gap setting. Adjust if
necessary.
Check rectifier output voltage.
Load drifts more than 4 inches
[100mm]
Brake lining worn
Air gap on brake is too wide
Replace wear items as
necessary
Adjust air gap setting
Travel direction does not
correspond to that indicated on
push button
Power supply incorrectly
connected
See SECTION 3
Abnormal noises while lifting or
lowering
Load chain and its components
are not lubricated
Clean and lubricate load chain.
Load chain is worn
Replace chain
Chain wheel or chain guide is
worn
Replace chain wheel or chain
guide
Idler sprocket is worn
Replace idler sprocket
A supply phase is missing
Connect the three phases
Twist or kink in load chain
Remove twist or kink