DC VOLTAGE

Range Resolution

Accuracy

3V 1mV

30V 10mV

300V 0.1V

±0.8% of rdg ± 1 digit

1000V 1V

±1.0% of rdg ± 2 digits

Input Impedance: 10M

Ω

AC VOLTAGE

Range Resolution

Accuracy

3V 1mV

30V 10mV

300V 0.1V

±1.0% of rdg ± 5 digits

750V 1V

±1.2 % of rdg ± 5 digits

Input Impedance: 10M

Ω

Frequency range: 40Hz to 200Hz.
Response: Average responding, calibrated in rms. of a sine wave.

AC CURRENT

Range Resolution

Accuracy

300A 0.1A

1000A 1A

< 600A ±2.0% of rdg ± 10 digits
> 600A ±3.0% of rdg ± 10 digits

Overload Protection: 1200A for 60 seconds maximum.
Frequency range: 50Hz to 60Hz.

DC CURRENT

Range Resolution

Accuracy

300A 0.1A

< 600A ±2.0% of rdg ± 5 digits