beautypg.com

Prokit's Industries MT-8006B User Manual

Page 15

background image

Caution:

If the Data Diver connected to a line with voltage over 100V, the fuse

will be blown, and it may also caused the IC protection function to

start and lock the Data Diver. When it happens, please remove all

batteries, and wait for 5-10 minutes until all power is dissipated, then

place the batteries back and restart the Data Diver.

Defect Situation

Possible Problem

Solution

Dead, Doesn’t
work

Blown fuse/IC protection
locked

Change new fuse
Remove the batteries,
wait for 5-10mins and
restart the Data Diver

No tone

Angled bed of nails are
not well connected

Check if Angled bed of
nails are well connected
to telecom line

Speakerphone
doesn’t work

MUTE button was
pressed and MUTE LED
indicator lights up

Press the MUTE button
and check if the MUTE
LED is off

Short rings only

Low battery /the angled
bed of nails are
connected to the power
source

Change new battery
Confirm if the angled
bed of nails connected
to the right telecom line

Can not hear the
conversation on
the Monitor status

The switch did not set to
“Mon” position
Low battery

Set the switch to “M”
position / Change a new
battery

Crosstalk

Angled bed of nails are
not connected firmly
The interference from
the telecom line

Check if the Angled bed
of nails are well
connected

Memory of storing
numbers doesn’t
work

Low battery

Change new battery

Polarity LED
doesn’t work

Low battery

Change new battery

HI (LED)
doesn’t work

Low battery

Change new battery

BATT(LED)
doesn’t work

Low battery

Change new battery

14