MAINTENANCE

WARNING:

To avoid electric shock, do not perform any servicing other

than that contained in the operating instructions unless you

are qualified to do so.

Disconnect clips from any metallic connections before

performing any maintenance.

If moisture should get inside the Data Diver, let the Data Diver dry at

normal room temperature for 24 hours. DO NOT HEAT THE DATA

DIVER. Moisture can provide a leakage path that may conduct

hazardous voltages to you. DO NOT USE the Data Diver if wet.

Keypad Care

Daily use of your Data Diver results in various liquids, dirt, and other

foreign material building up in your keypad. The keypad may be

cleaned by using a soft toothbrush with soap and water.

Do not use a petroleum-based or chlorinated cleaning agent as it will

harm the keypad. Let the Data Diver dry before using!

Data Diver Trouble Shooting:

1. The MT-8006B Data Diver is a professional telecom tool,

especially designed for checking telecom lines. It is not allowed to

be used under the power source AC100~125V 50/60Hz or

AC200~250V 50/60Hz; otherwise, it may cause the danger of

electric shock or product damage.

2. If there is any crosstalk in application, generally it is the

interference from the telecom line; please check if the angled bed

of nail clips well connected to the telecom line.

3. If any abnormal situation is found while you are using the Prokit's

Data Diver, please test the other telecom line in the different area

to identify the possible defective situation referring to the trouble

shooting list below. (Attention! Please never have the angled bed

of nail clips connected to the power source for safety reason.)

4. If the Data Diver still doesn't work after the first step of fix-up,

please send back to Prokit’s distributor for repairing

13