background image

2

DURING USE
 Never exceed the protection limit values indicated in

specifications for each range of measurement.

 When the meter is linked to measurement circuit, do not touch

unused terminals.

 Never use the meter to measure voltages that might exceed

500V above earth ground in category III

installations.

 When the value scale to be measured is unknown, set the

range selector at the highest position.

 Before rotating the function / range selector to change

functions, disconnect test leads from the circuit under test.

 When carrying out measurements on TV or switching power

circuits always remember that there may be high amplitude
voltages pulses at test points, which can damage the meter.

 Always careful when working with voltages above 60V DC or

30V AC rms. Keep fingers behind the probe barriers while
measuring.

 Before attempting to insert transistors for testing, always be

sure that test leads have been disconnected from any
measurement circuits.

 Components should not be connected to the hFE socket when

making voltage measurements with test leads.

 Never perform resistance measurements on live circuits.

GENERAL DESCRIPTION
The meter is a handheld 3 1/2 digital multimeter for measuring
DC and AC voltage, DC current, Resistance, Diode, Transistor
and Continuity Test with battery operated.