Prokit's Industries NT-6570 User Manual
Page 6

value is clearly visible on the LCD
Voice data report
Click the button to change to the Beep/English Voice/Chinese
Voice data report function.
Distance unit setting for instrument
Click the button to change to the next type of unit, m, ft., in,
ft+in then continue to click the button to the next unit selection.
MEASUREMENT
Single distance measurement
Press this button to activate the laser. Press again to trigger the
distance measurement. The measured value is displayed
immediately.
Continuous Measurement (Tracking) & Maximum and
Minimum Measurement
The continuous measurement function (tracking)
is used for the transferring of measurements, e.g.,
from construction plans. In continuous
measurement mode, the measuring tool can be
moved close to the target, whereby the measured
value is updated approx. every 0.5 seconds. The
corresponding dynamically minimum and
maximum values are displayed in the first and
second line.
As an example, the user can move from a wall to
the required distance, while the actual distance can be read
continuously. For continuous measurement, push button until
the indicator for continuous measurement appears in the display.
And press it again or to stop the function. The function is
terminated after continuous measurement for 3 minutes.
fig.D
- 5 -