beautypg.com

MAX Power VIP 150 Electric Retractable Thruster User Manual

Page 8

background image

VIP 150, 12/24V with Electronic Controller

.

25/12/05

8


f) When finished with the final adjustments, fix the alloy plate bracket by bolting through

the GRP turbine in addition to the cable clamps.

IMPORTANT: Please keep in mind that the power supply to up/down motors is not

automatically interrupted if the proximity switches do not detect the position detectors. Care

must therefore be taken to remove ones finger from up or down button as soon as the unit

blocks in fully up or fully down position when closing plate adjustments are done and if

position detectors are not adjusted yet.

-

12 V / 24V
Depending on
motor voltage.

+

Fuse
( 10 A )

-

+

-

+

Up/Down
Motors

Adjusment
Nuts

( b )

( b )

( a )

4. ELECTRICAL

INSTALLATION

4.1 GENERAL:

It is important that a qualified marine electrician does the electrical installation, since an

incorrect electrical installation will result in the rapid deterioration and/or failure of the unit.

All electrical components (thruster motor, relay, electronic control box, ect…) should be
installed in dry and ventilated areas.

Under no circumstances should any inflammable products be stored next to the electrical

components of the thruster.

When choosing cable sizes and the battery bank size and type, special care should be given
to voltage drops, since excessive voltage drops will cause premature failure of motors and

relay contacts.

Great care should be taken to correctly tighten all electrical connections.


Installation Advise: In order to make sure that VIP is

raising and lowering smoothly and when closing plate

adjustments are made, one can do the following:

a) Connect 12/24V (depending on thruster voltage)

directly to the two up/down motors and simply

reverse the polarity to change direction

(raise/lower).

It is important to install a 10A fuse in the

positive cable and to keep in mind that wires

need to be disconnected as soon as the up or

down position is reached or as soon as the unit

blocks, to avoid damaging the up/down motors.

b) If the unit blocks before reaching the up/down

position or if the unit vibrates excessively when

going up/down one needs to adjust the two

adjustment nuts to ensure the unit is completely

vertical to its base.