3.2 CONSTRUCTION OF HULL OPENING & CLOSING PLATE:

The opening made for the thruster in the hull is closed by a plate, which can be made
from the cutout hull section, or specially fabricated.


Hull
Closing
Plate

15 - 20 mm
wide rebate
in hull.

Hull

( a )

( c )

( b )


To prevent marine growth inside the turbine enclosure, it is essential that once the unit is

raised, no light be allowed to enter.
On an excellent installation the enclosure may even be watertight. If this is achieved

anode life will be greatly increased (No circulating water, no oxygen and no corrosion!).

The use of antifouling or other paints on the thruster unit is not necessary if the closing
plate closes properly onto its seal.

However, if painted, never use copper based paints and do not paint the vertical

column of the unit.


3.3 FINAL FITTING OF THE THRUSTER UNIT TO THE MOUNTING BASE:

Final installation of the thruster unit onto the mounting base must be made after

thoroughly cleaning and then liberally coating both joint surfaces (thruster base flange
and mounting base flange) with good quality marine grease. This is so that the «O» ring

seal is compressed flat, evenly, smoothly and squarely when the bolts are tightened.


Under no circumstances should the thruster be glued or bedded down with a marine type
mastic/glue such as Sikaflex or other similar product(s).

The flange bolts should be tightened sequentially and in successive passes until the two

surfaces touch.

a) The closing plate should fit into a 15 – 20

mm wide rebate in the hull when in the

raised position. This is to transfer all the seas
slamming forces to the hull and not to the

electric rams!

b) The closing plate must be securely fixed to

the supplied adjustable aluminium-mounting

fitting.

c) A gasket must be installed in the hulls

rebate. This gasket can be made either from

neoprene or moulded in «SIKAFLEX» (or
similar product). Precautions should be taken

to ensure that the gasket does not stick to
the closing plate. The plate must rest evenly

on this gasket when the thruster is closed.