Visit the Peerless Web Site at www.peerlessmounts.com

3 of 5

E

F

A

solid concrete

cinder block

Installation to Solid Concrete or Cinder Block

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual

concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount

in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM

C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a

hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware

and components.

WARNING

1

CUT

AW

AY

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/

dry wall

plaster/

dry wall

concrete

concrete

1

3

2

F

Drill holes and insert anchors (

F).

Place plate (

A) over anchors (E) and secure with screws (F).

Tighten all fasteners.

A

F

E

concrete

surface

• Tighten screws so that wall plate is firmly attached,

but do not overtighten. Overtightening can damage

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to

concrete covered with plaster, drywall, or other

finishing material. If mounting to concrete surfaces

covered with a finishing surface is unavoidable,

the finishing surface must be counter bored as

shown below. Be sure concrete anchors do not

pull away from concrete when tightening screws. If

plaster/drywall is thicker than 5/8" (16 mm), custom

fasteners must be supplied by installer

WARNING

Make sure that wall plate (

A) is level, use it as a

template to mark six mounting holes. Drill six 5/16”

(8mm) dia. holes to a minimum depth of 2.5” (64

mm). Insert anchors (

F) in holes flush with wall as

shown (right). Place wall plate (

A) over anchors and

secure with six #14 x 2.5” screws (

E) as shown.