7. Slide the new batteries into EBM.
8. Reconnect the battery cable and screw up the battery bracket.
9. Close and reinstall the front panel back to EBM.
7. COMMUNICATION PORT
7.1 RS232 + Dry contact (750/1000/1500/2000/3000VA):
DB9 Female (RS232 +dry contact)
PIN #
Description
I/O
Function Explanation
1 DCD
Output Low
Battery
Output
(*normally open, pull
to Pin#5 when
battery low alarm in
battery mode)
2 RxD
Output RxD
3 TxD
Input TxD
4
DTR
Input
(tied to pin 6)
5
Common
--
Common (tied to
chassis)
6
DSR
Output
(tied to pin 4)
7 RTS
Input No
connection
8
CTS
Output
AC Fail Output
(*normally open, pull
to Pin#5 when UPS
is in battery mode).
7.2 USB port: HID protocol
The USB and RS232 are unable to operate at the same time. Either
only USB or DB9 can connect with RS-232 at one time, usually
connecting with USB function is priority.