5 configuration register 1-address 40h, 6 interrupt status register 1-address 41h, Functional description – Rainbow Electronics LM87 User Manual
Page 26
![background image](/manuals/282249/26/background.png)
Functional Description
(Continued)
13.5 Configuration Register 1 — Address 40h
Power on default –
<
7:0
>
= 00001000 binary
Bit
Name
Read/Write
Description
0
Start
Read/Write
A one enables startup of monitoring operations, a zero puts the part in standby mode.
Note: The outputs of Interrupt pins will not be cleared if the user writes a zero to this
location after an interrupt has occurred, unlike the “INT_Clear” bit.
At start up, limit checking functions and scanning begin. Note, all limits should be set in
the Value RAM before setting this bit HIGH.
1
INT# Enable
Read/Write
A one enables the INT# Interrupt output.
2
THERM#
Enable
Read/Write
A one enables the THERM# Interrupt output.
3
INT#_Clear
Read/Write
A one disables the INT# output without affecting the contents of Interrupt Status
Registers. The device will stop monitoring. It will resume upon clearing of this bit.
4
RESET#
Read/Write
A one outputs a 20 ms minimum active low reset signal at RESET#. This bit is cleared
once the pulse has gone inactive.
5
Reserved
Read/Write
6
THERM#_Clear
Read/Write
A one disables the THERM# output without affecting the contents of Interrupt Status
Registers.
7
INITIALIZATION
Read/Write
A one restores power on default values to the Configuration Register, Interrupt Status
Registers, Interrupt Mask Registers, CI Clear Register, VID/Fan Divisor Register, VID4,
Temperature Configuration Register, and the Extended Mode Registers. This bit clears
itself since the power on default is zero.
13.6 Interrupt Status Register 1 — Address 41h
Power on default –
<
7:0
>
= 0000 0000 binary
Bit
Name
Read/Write
Description
0
+2.5Vin
Read Only
A one indicates a High or Low limit has been exceeded.
1
Vccp1
Read Only
A one indicates a High or Low limit has been exceeded.
2
Vcc
Read Only
A one indicates a High or Low limit has been exceeded.
3
+5Vin
Read Only
A one indicates a High or Low limit has been exceeded.
4
Int. Temp.
Read Only
A one indicates a High or Low limit has been exceeded.
5
Ext. Temp.
Read Only
A one indicates a High or Low limit has been exceeded.
6
FAN1/AIN1
Read Only
A one indicates the fan count limit has been exceeded or an AIN1 High or Low limit has
been exceeded.
7
FAN2/AIN2
Read Only
A one indicates the fan count limit has been exceeded or an AIN2 High or Low limit has
been exceeded.
LM87
www.national.com