MAX1027/MAX1029/MAX1031

10-Bit 300ksps ADCs with FIFO,

Temp Sensor, Internal Reference

_______________________________________________________________________________________

5

Note 9: This time is defined as the number of clock cycles needed for conversion multiplied by the clock period. If the internal refer-

ence needs to be powered up, the total time is additive. The internal reference is always used for temperature measurements.

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Externally clocked conversion

208

SCLK Clock Period

t

CP

Data I/O

100

ns

SCLK Duty Cycle

t

CH

40

60

%

SCLK Fall to DOUT Transition

t

DOT

C

LOAD

= 30pF

40

ns

CS Rise to DOUT Disable

t

DOD

C

LOAD

= 30pF

40

ns

CS Fall to DOUT Enable

t

DOE

C

LOAD

= 30pF

40

ns

DIN to SCLK Rise Setup

t

DS

40

ns

SCLK Rise to DIN Hold

t

DH

0

ns

CS to SCLK Rise Setup

t

CSS

40

ns

SCLK Rise to

CS Hold

t

CSH

0

ns

t

CSW

CKSEL = 00, CKSEL = 01 (temp sense)

40

ns

CNVST Pulse Width

CKSEL = 01 (voltage conversion)

1.4

µs

t

T S

Temp sense

56

Voltage conversion

7

CS or CNVST Rise to EOC
Low (Note 9)

t

R P

Reference power-up

65

µs

TIMING CHARACTERISTICS (Figure 1)

-0.4

-0.3

-0.2

-0.1

0

0.1

0.2

0.3

0.4

0

256

512

768

1024

INTEGRAL NONLINEARITY

vs. OUTPUT CODE

MAX1027/29/31 toc01

OUTPUT CODE

INTEGRAL NONLINEARITY (LSB)

-0.4

-0.3

-0.2

-0.1

0

0.1

0.2

0.3

0.4

0

256

512

768

1024

DIFFERENTIAL NONLINEARITY

vs. OUTPUT CODE

MAX1027/29/31 toc02

OUTPUT CODE

DIFFERENTIAL NONLINEARITY (LSB)

SINAD vs. FREQUENCY

MAX1027/29/31 toc03

FREQUENCY (kHz)

SINAD AMPLITUDE (dB)

100

10

1

10

20

30

40

50

60

70

80

90

100

0

0.1

1000

Typical Operating Characteristics

(V

DD

= +3V, V

REF

= +2.5V, f

SCLK

= 4.8MHz, C

LOAD

= 30pF, T

A

= +25°C, unless otherwise noted.)