MAX1027/MAX1029/MAX1031
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
_______________________________________________________________________________________
5
Note 9: This time is defined as the number of clock cycles needed for conversion multiplied by the clock period. If the internal refer-
ence needs to be powered up, the total time is additive. The internal reference is always used for temperature measurements.
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Externally clocked conversion
208
SCLK Clock Period
t
CP
Data I/O
100
ns
SCLK Duty Cycle
t
CH
40
60
%
SCLK Fall to DOUT Transition
t
DOT
C
LOAD
= 30pF
40
ns
CS Rise to DOUT Disable
t
DOD
C
LOAD
= 30pF
40
ns
CS Fall to DOUT Enable
t
DOE
C
LOAD
= 30pF
40
ns
DIN to SCLK Rise Setup
t
DS
40
ns
SCLK Rise to DIN Hold
t
DH
0
ns
CS to SCLK Rise Setup
t
CSS
40
ns
SCLK Rise to
CS Hold
t
CSH
0
ns
t
CSW
CKSEL = 00, CKSEL = 01 (temp sense)
40
ns
CNVST Pulse Width
CKSEL = 01 (voltage conversion)
1.4
µs
t
T S
Temp sense
56
Voltage conversion
7
CS or CNVST Rise to EOC
Low (Note 9)
t
R P
Reference power-up
65
µs
TIMING CHARACTERISTICS (Figure 1)
-0.4
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.4
0
256
512
768
1024
INTEGRAL NONLINEARITY
vs. OUTPUT CODE
MAX1027/29/31 toc01
OUTPUT CODE
INTEGRAL NONLINEARITY (LSB)
-0.4
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.4
0
256
512
768
1024
DIFFERENTIAL NONLINEARITY
vs. OUTPUT CODE
MAX1027/29/31 toc02
OUTPUT CODE
DIFFERENTIAL NONLINEARITY (LSB)
SINAD vs. FREQUENCY
MAX1027/29/31 toc03
FREQUENCY (kHz)
SINAD AMPLITUDE (dB)
100
10
1
10
20
30
40
50
60
70
80
90
100
0
0.1
1000
Typical Operating Characteristics
(V
DD
= +3V, V
REF
= +2.5V, f
SCLK
= 4.8MHz, C
LOAD
= 30pF, T
A
= +25°C, unless otherwise noted.)