Internally Timed Acquisitions and

Conversions Using the Serial Interface

Performing Conversions in Clock Mode 10

In clock mode 10, the wake up, acquisition, conversion,
and shutdown sequences are initiated by writing an
input data byte to the conversion register, and are per-
formed automatically using the internal oscillator. This
is the default clock mode upon power-up. See Figure 6
for clock mode 10 timing.

Initiate a scan by writing a byte to the conversion regis-
ter. The MAX1027/MAX1029/MAX1031 then power up,
scan all requested channels, store the results in the

FIFO, and shut down. After the scan is complete, EOC
is pulled low and the results are available in the FIFO. If
a temperature measurement is requested, the tempera-
ture result precedes all other FIFO results. EOC stays
low until CS is pulled low again.

Externally Clocked Acquisitions and

Conversions Using the Serial Interface

Performing Conversions in Clock Mode 11

In clock mode 11, acquisitions and conversions are ini-
tiated by writing to the conversion register and are per-
formed one at a time using the SCLK as the conversion

CS

DOUT

SCLK

CNVST

EOC

(CONVERSION2)

MSB1

LSB1

MSB2

(ACQUISITION1)

(ACQUISITION2)

(CONVERSION1)

REQUEST MULTIPLE CONVERSIONS BY SETTING CNVST LOW FOR EACH CONVERSION.

X = DON'T CARE.

Figure 5. Clock Mode 01

(UP TO 514 INTERNALLY CLOCKED ACQUISITIONS AND CONVERSIONS)

MSB2

(CONVERSION BYTE)

CS

DOUT

SCLK

DIN

EOC

THE CONVERSION BYTE BEGINS THE ACQUISITION. CNVST IS NOT REQUIRED.

X = DON'T CARE.

MSB1

LSB1

Figure 6. Clock Mode 10