ELECTRICAL CHARACTERISTICS (continued)

(V

CC

= +4.5V to +5.5V, AC-coupled (C = 0.01µF) output load

≥ 2kΩ, T

A

= -40°C to +105°C. Typical values are at V

CC

= +5V,

T

A

= +25°C, unless otherwise noted.) (Note 1)

PARAMETER SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

ATT = 0

-71

Attenuation in Disable Mode

Frequency < 5MHz,
20log(V

OUT_DISABLED

/

V

OUT_ENABLED

)

ATT = 1

-57

dB

At 1MHz, DIS = 0, ATT = 0, GAIN = 0 or 1

51

At 1MHz, DIS = 0, ATT = 1, GAIN = 0 or 1

114

Output Impedance

At 1MHz, DIS = 1, ATT = 0 or 1, GAIN = 0
or 1

9 k

Note 1: AC specifications are guaranteed by design and characterization.
Note 2: Supply current is measured with OUT unterminated or AC-coupled.
Note 3: Measured by applying 100mV

P-P

sinusoidal noise to the supply voltage. PSNR is defined as 20log(V

OUT_NOISE

/V

CC_NOISE

).

SUPPLY CURRENT vs. TEMPERATURE

MAX3806 toc01

TEMPERATURE (NC)

SUPPLY CURRENT (mA)

85

60

-15

10

35

2

4

6

8

10

12

14

16

0

-40

110

DIS = 0

DIS = 1

OUTPUT VOLTAGE vs. INPUT CURRENT

MAX3806 toc02

INPUT CURRENT (µA

P

)

OUTPUT VOLTAGE (V

P

)

100

10

1

0.01

0.1

1

10

0.001

0.1

1000

GAIN = 0, ATT = 0

GAIN = 1, ATT = 1

GAIN = 0, ATT = 1

GAIN = 1, ATT = 0

FREQUENCY RESPONSE

MAX3806 toc03

FREQUENCY (MHz)

TRANSIMPEDANCE (dB

I

)

10

1

65

70

75

80

85

90

95

100

105

60

0.1

100

GAIN = 1, ATT = 0

GAIN = 0, ATT = 0

GAIN = 1, ATT = 1

GAIN = 0, ATT = 1

Typical Operating Characteristics

(Typical values are at V

CC

= +5V, T

A

= +25

°C, C