AC ELECTRICAL CHARACTERISTICS
(Over the Operating Range)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Read Cycle Time
t
RC
120
ns
Address Access Time
t
AA
120
ns
CE
Access Time
t
CEA
120
ns
CE
Data Off Time
t
CEZ
40
ns
Output Enable Access Time
t
OEA
100
ns
Output Enable Data Off Time
t
OEZ
40
ns
Output Enable to DQ Low-Z
t
OEL
5
ns
CE
to DQ Low-Z
t
CEL
5
ns
Output Hold from Address
t
OH
5
ns
Write Cycle Time
t
WC
120
ns
Address Setup Time
t
AS
0
ns
CE
Pulse Width
t
CEW
100
ns
Address Hold from End of Write
t
AH1
t
AH2
5
30
ns
ns
5
6
Write Pulse Width
t
WEW
75
ns
WE
Data Off Time
t
WEZ
40
ns
WE
or
CE
Inactive Time
t
WR
10
ns
Data Setup Time
t
DS
85
ns
Data Hold Time High
t
DH1
t
DH2
0
25
ns
ns
5
6
AC TEST CONDITIONS
Input Levels:
0V to 3V
Transition Times:
5 ns
CAPACITANCE (t
A
= 25
°C)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS NOTES
Capacitance on all pins (except DQ)
C
I
7
pF
Capacitance on DQ pins
C
DQ
10
pF
AC ELECTRICAL CHARACTERISTICS
(POWER-UP/DOWN TIMING)
(Over the Operating Range)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS NOTES
CE
or
WE
at V
IH
before Power-Down
t
PD
0
ms
V
PF
(Max) to V
PF
(Min) V
CC
Fall Time
t
F
300
ms
V
PF
(Min) to V
SO
V
CC
Fall Time
t
FB
10
ms
V
SO
to V
PF
(Min) V
CC
Rise Time
t
RB
1
ms
V
PF
(Min) to V
PF
(Max) V
CC
Rise Time
t
R
0
ms
Power-Up
t
REC
15
35
ms
Expected Data Retention Time
(Oscillator On)
t
DR
10
years
4