MEMORY AC ELECTRICAL CHARACTERISTICS Over the operating range (5V)

DS1251Y-70

PARAMETER

SYMBOL

MIN

MAX

UNITS

NOTES

Read Cycle Time

t

RC

70

ns

Access Time

t

ACC

70

ns

OE

to Output Valid

t

OE

35

ns

CE

to Output Valid

t

CO

70

ns

OE

or

CE

to Output Active

t

COE

5

ns

5

Output High-Z from Deselection

t

OD

25

ns

5

Output Hold from Address Change

t

OH

5

ns

Write Cycle Time

t

WC

70

ns

Write Pulse Width

t

WP

50

ns

3

Address Setup Time

t

AW

0

ns

Write Recovery Time

t

WR

0

ns

Output High-Z from

WE

t

ODW

25

ns

5

Output Active from

WE

t

OEW

5

ns

5

Data Setup Time

t

DS

30

ns

4

Data Hold Time from

WE

t

DH

5

ns

4