Rainbow Electronics DS1339 User Manual
Page 5
DS1339
5 of 18
Figure 2. DS1339 TIMEKEEPER REGISTERS
ADDRESS
BIT7
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
FUNCTION
RANGE
00H
0
10 SECONDS
SECONDS
Seconds
00–59
01H
0
10 MINUTES
MINUTES
Minutes
00–59
AM/PM
02H
0
12/24
10HR
10HR
HOUR
Hours
1–12 +
AM/PM
00–23
03H
0
0
0
0
0
DAY
Day
1–7
04H
0
0
10 DATE
DATE
Date
00–31
05H
CENTURY
0
0
10 MO
MONTH
Month/
Century
01–12 +
Century
06H
10 YEAR
YEAR
Year
00–99
07H
A1M1
10 SECONDS
SECONDS
Alarm 1
Seconds
00–59
08H
A1M2
10 MINUTES
MINUTES
Alarm 1
Minutes
00–59
AM/PM
09H
A1M3
12/24
10HR
10HR
HOUR
Alarm 1
Hours
1–12 +
AM/PM
00-23
0AH
A1M4
DY/DT
10 DATE
DAY
DATE
Alarm 1
Day
Alarm 1
Date
1–7
1–31
0BH
A2M2
10 MINUTES
MINUTES
Alarm 2
Minutes
00–59
AM/PM
0CH
A2M3
12/24
10HR
10HR
HOUR
Alarm 2
Hours
1–12 +
AM/PM
00–23
0DH
A2M4
DY/DT
10 DATE
DAY
DATE
Alarm 2
Day
Alarm 2
Date
1–7
1–31
0EH
EOSC
0
BBSQI
RS2
RS1
INTCN
A2IE
A1IE
Control
—
0FH
OSF
0
0
0
0
0
A2F
A1F
Status
—
10H
TCS3
TCS2
TCS1
TCS0
DS1
DS0
ROUT1
ROUT0
Trickle
Charge
—
Note: Unless otherwise specified, the registers’ state are not defined when power is first applied or V
CC
and V
BACKUP
falls below the V
BACKUP
min.