Ac electrical characteristics – Rainbow Electronics DS1339 User Manual
Page 16
DS1339
16 of 18
AC ELECTRICAL CHARACTERISTICS
(V
CC
= MIN to MAX, T
A
= -40
°C to +85°C) (Note 12)
PARAMETER
SYMBOL CONDITION
MIN
TYP
MAX UNITS NOTES
Fast Mode
100
400
SCL Clock
Frequency
f
SCL
Standard Mode
100
kHz
Fast Mode
1.3
Bus Free Time
Between a STOP
and START
Condition
t
BUF
Standard Mode
4.7
ms
Fast Mode
0.6
Hold Time
(Repeated) START
Condition
t
HD:STA
Standard Mode
4.0
ms
5
Fast Mode
1.3
LOW Period of
SCL Clock
t
LOW
Standard Mode
4.7
ms
Fast Mode
0.6
HIGH Period of
SCL Clock
t
HIGH
Standard Mode
4.0
ms
Fast Mode
0.6
Setup Time for a
Repeated START
Condition
t
SU:STA
Standard Mode
4.7
ms
Fast Mode
0
0.9
Data Hold Time
t
HD:DAT
Standard Mode
0
ms
6, 7
Fast Mode
100
Data Setup Time
t
SU:DAT
Standard Mode
250
ns
9
Fast Mode
300
Rise Time of Both
SDA and SCL
Signals
t
R
Standard Mode
20 + 0.1C
B
1000
ns
8
Fast Mode
Fall Time of Both
SDA and SCL
Signals
t
F
Standard Mode
20 + 0.1C
B
300
ns
8
Fast Mode
0.6
Setup Time for
STOP Condition
t
SU:STO
Standard Mode
4.0
ms
Capacitive Load for
Each Bus Line
C
B
400
pF
8
I/O Capacitance
C
I/O
10
pF
Oscillator Stop Flag
(OSF) Delay
t
OSF
100
ms
11