MAX5510/MAX5511

+1.8V to +5.5V, Ultra-Low-Power, 8-Bit,

Voltage-Output DACs

______________________________________________________________________________________

13

CONTROL BITS

INPUT DATA

SUB-BITS

C3

C2

C1

C0

D7–D0

S3–S0

FUNCTION

0

0

0

0

XXXXXXXX

0000

No operation; command is ignored.

0

0

0

1

8-bit data

0000

Load input register from shift register; DAC register
unchanged; DAC output unchanged.

0

0

1

0

Command reserved; do not use.

0

0

1

1

Command reserved; do not use.

0

1

0

0

Command reserved; do not use.

0

1

0

1

Command reserved; do not use.

0

1

1

0

Command reserved; do not use.

0

1

1

1

Command reserved; do not use.

1

0

0

0

8-bit data

0000

Load DAC register from input register; DAC output
updated; MAX5510 enters normal operation if in
shutdown; MAX5511 enters normal operation if in
standby or shutdown.

1

0

0

1

8-bit data

0000

Load input register and DAC register from shift register;
DAC output updated; MAX5510 enters normal operation
if in shutdown; MAX5511 enters normal operation if in
standby or shutdown.

1

0

1

0

Command reserved; do not use.

1

0

1

1

Command reserved; do not use.

1

1

0

0

D7, D6,

XXXXXX

0000

MAX5510 enters shutdown; MAX5511 enters standby*.
For the MAX5511, D7 and D6 configure the internal
reference voltage (Table 3).

1

1

0

1

D7, D6,

XXXXXX

0000

MAX5510/MAX5511 enter normal operation; DAC output
reflects existing contents of DAC register. For the
MAX5511, D7 and D6 configure the internal reference
voltage (Table 3).

1

1

1

0

D7, D6,

XXXXXX

0000

MAX5510/MAX5511 enter shutdown; DAC output set to
high impedance. For the MAX5511, D7 and D6 configure
the internal reference voltage (Table 3).

1

1

1

1

8-bit data

0000

Load input register and DAC register from shift register;
DAC output updated; MAX5510 enters normal operation
if in shutdown; MAX5511 enters normal operation if in
standby or shutdown.

Table 2. Serial-Interface Programming Commands

X = Don’t care.
*Standby mode can be entered from normal operation only. It is not possible to enter standby mode from shutdown.