Typical operating characteristics (continued) – Rainbow Electronics MAX19507 User Manual
Page 11

Typical Operating Characteristics (continued)
(V
AVDD
= V
OVDD
= 1.8V, internal reference, differential clock, V
CLK
= 1.5V
P-P
, f
CLK
= 130MHz, A
IN
= -0.5dBFS, data output termina-
tion = 50Ω, T
A
= +25°C, unless otherwise noted.)
COMMON-MODE VOLTAGE
vs. TEMPERATURE
MAX19507 toc30
TEMPERATURE (°C)
COMMON-MODE VOLTAGE (V)
60
10
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0
-40
V
CM
= 1.35V
V
CM
= 1.2V
V
CM
= 1.05V
V
CM
= 0.9V
V
CM
= 0.75V
V
CM
= 0.6V
V
CM
= 0.45V
OFFSET ERROR
vs. TEMPERATURE
MAX19507 toc28
TEMPERATURE (°C)
OFFSET ERROR (mV)
60
10
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
0.1
0.2
-0.7
-40
MAX19507
Dual-Channel, 8-Bit, 130Msps ADC
______________________________________________________________________________________
11
REFERENCE VOLTAGE
vs. TEMPERATURE
MAX19507 toc29
TEMPERATURE (°C)
REFERENCE VOLTAGE (V)
60
10
1.2453
1.2474
1.2495
1.2516
1.2432
-40
GAIN ERROR vs. SUPPLY VOLTAGE
SUPPLY VOLTAGE (V)
GAIN ERROR (%)
MAX19507 toc31
1.6
2.1
2.6
3.1
3.6
-0.08
-0.06
-0.04
-0.02
0
0.02
0.04
0.06
0.08
REGULATOR MODE
INPUT CURRENT
vs. COMMON-MODE VOLTAGE
COMMON-MODE VOLTAGE (V)
INPUT CURRENT (
µ
A)
MAX19507 toc32
0.4
0.6
0.8
1.0
1.2
1.4
40
50
60
70
80
90
100
110