MAX6649

+145°C Precision SMBus-Compatible Remote/
Local Sensor with Overtemperature Alarms

10

______________________________________________________________________________________

Valid A/D conversion results for both channels are avail-
able one total conversion time (125ms nominal, 156ms
maximum) after initiating a conversion, whether conver-
sion is initiated through the RUN bit, one-shot com-
mand, or initial power-up. Changing the conversion rate
can also affect the delay until new results are available.

Slave Addresses

The MAX6649 has a fixed address of 1001 100. The
MAX6649 also responds to the SMBus alert response

slave address (see the Alert Response Address section).

POR and UVLO

To prevent ambiguous power-supply conditions from
corrupting the data in memory and causing erratic
behavior, a POR voltage detector monitors V

CC

and

clears the memory if V

CC

falls below 2.0V (typ). When

power is first applied and V

CC

rises above 2.0V (typ),

the logic blocks begin operating, although reads and

REGISTER

ADDRESS

POR STATE

FUNCTION

RLTS

00h

0000 0000

0°C

Read local (internal) temperature

RRTE

01h

0000 0000

0°C

Read remote (external) temperature

RSL

02h

N/A

Read status byte

RCL

03h

0000 0000

Read configuration byte

RCRA

04h

0000 0111

Read conversion rate byte

RLHN

05h

0101 0101

+85°C

Read local (internal) ALERT high limit

RLLI

06h

0000 0000

0°C

Read local (internal) ALERT low limit

RRHI

07h

0101 0101

+85°C

Read remote (external) ALERT high limit

RRLS

08h

0000 0000

0°C

Read remote (external) ALERT low limit

WCA

09h

N/A

Write configuration byte

WCRW

0Ah

N/A

Write conversion rate byte

WLHO

0Bh

N/A

Write local (internal) ALERT high limit

WLLM

0Ch

N/A

Write local (internal) ALERT low limit

WRHA

0Dh

N/A

Write remote (external) ALERT high limit

WRLN

0Eh

N/A

Write remote (external) ALERT low limit

OSHT

0Fh

N/A

One-shot

REET

10h

0000 0000

0°C

Read remote (external) extended temperature

RIET

11h

0000 0000

0°C

Read local (internal) extended temperature

RWOE

19h

0101 0101

+85°C

Read/write remote (external) OVERT limit (MAX6649)

RWOI

20h

0101 0101

+85°C

Read/write local (internal) OVERT limit

HYS

21h

0000 1010

10°C

Overtemperature hysteresis

QUEUE

22h

1000 0110

Fault queue

FEh

0100 1101

Read manufacture ID

FFh

0101 1001

Read revision ID

Table 5. Command-Byte Bit Assignments

BIT

NAME

POR STATE

FUNCTION

7 (MSB)

MASK

0

Masks ALERT interrupts when set to 1.

6

RUN

0

Standby mode control bit; if set to 1, standby mode is initiated.

5 to 0

RFU

0

Reserved.

Table 6. Configuration-Byte Bit Assignments (03h)