Heater installation, Transition hi-limit installation – Grain Systems PNEG-377 User Manual
Page 34
34
Fan and Heater
HEATER INSTALLATION
Air Pressure Switch and
Temperature Sensor Box
Installation
1. Using air switch box as a
guide, mark 2 holes on ple-
num side wall appproximately
24" to right of transition cen-
tered up and down in plenum.
2. Drill air switch filter hole 5/8"
diameter for snug fit. Drill tem-
perature sensor hole 5/8" or
larger to accommodate mounting
nut.
3. Mount Box to Bin using (4)
self drilling screws
4. Caulk between housing and side-
wall to seal.
Air Switch Box Assembly
1. Mark location on transition
one (1) foot up from the bot-
tom (entrance collar) and
cen-
tered in the tran-
sition.
2. Drill or knock out 7/8" diam-
eter hole on marked location.
3. Install transition hi-limit using
supplied self drilling screws.
Transition Hi-limit Installation
Figure 1: The transition connecting the Series 2000 Heater to the bin with the
plenum sensor in place.
- PNEG-1890 (16 pages)
- PNEG-595 (26 pages)
- PNEG-1472 (30 pages)
- PNEG-897 (58 pages)
- PNEG-838 (4 pages)
- PNEG-1755 (36 pages)
- PNEG-524 (24 pages)
- PNEG-1080 (2 pages)
- PNEG-728 (47 pages)
- PNEG-673 (57 pages)
- PNEG-1717 (88 pages)
- PNEG-823 (42 pages)
- PNEG-630-6S (23 pages)
- PNEG-1876 (80 pages)
- PNEG-102 (2 pages)
- PNEG-366 (51 pages)
- PNEG-1626 (1 page)
- PNEG-1874 (78 pages)
- PNEG-1798 (34 pages)
- PNEG-1927 (4 pages)
- PNEG-924 (2 pages)
- PNEG-582 (26 pages)
- PNEG-012 (46 pages)
- PNEG-1797 (86 pages)
- PNEG-546 (26 pages)
- PNEG-951 (102 pages)
- PNEG-1650 (92 pages)
- PNEG-1649 (50 pages)
- PNEG-1376 (88 pages)
- PNEG-361 (46 pages)
- PNEG-338 (32 pages)
- PNEG-1276 (78 pages)
- PNEG-1283 (22 pages)
- PNEG-1089 (14 pages)
- QSG-001 (2 pages)
- PNEG-950 (96 pages)
- PNEG-1590 (3 pages)
- PNEG-501 (33 pages)
- PNEG-1447 (68 pages)
- PNEG-707GSI (446 pages)
- PNEG-349 (32 pages)
- PNEG-236 (22 pages)
- PNEG-743 (16 pages)
- PNEG-900 (54 pages)
- PNEG-1935 (92 pages)