Chapter 6: stiffeners – Grain Systems Tanks PNEG-4105 User Manual
Page 61
Close-Punch Connection for a Two-Ring Stiffener (0–14 Ga) to a
Base Stiffener (2–8 Ga)
Reference the following information when connecting a two-ring stiffener (CTS-2073XX) to a base stiffener
(CTS-2119XX).
Figure 6-15 Two-Ring Stiffener (0–14 Ga) to a Two-Ring Stiffener (2–8 Ga) Close-Punch Connection
A
Close-punch two-ring stiffener (CTS-2073XX)
B
Close-punch base stiffener (CTS-2119XX)
C
Splice (CTS-2091XX)
D
3/8 x 1 Bolt (S-7485)
E
3/8 Nut (S-9426)
F
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where holes
in the stiffeners align with holes in the sidewall
sheet.
Two-Ring Stiffener (0–14 Ga) to a Base Stiffener (10–16 Ga)
Connection
Reference the following information when connecting a two-ring stiffener (CTS-2063XX) to a base stiffener
(CTS-2123XX).
Figure 6-16 Two-Ring Stiffener (0–14 Ga) to a Base Stiffener (10–16 Ga) Connection
A
Two-ring stiffener (CTS-2063XX)
B
Base stiffener (CTS-2123XX)
C
Splice (CTS-2091XX)
D
3/8 x 1 Bolt (S-7485)
E
3/8 Nut (S-9426)
F
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
Pneg-4105 105 Ft Diameter 40-Series Bin
61