24

Series 2000 Downwind Heater

On hi-lo units when the unit reaches cycle set point, the flame will

switch to lo-flame and unit will not cycle back to hi-flame until (Set

Point minus Temperature Differential) is reached.

Temperature differential would normally be set for 10-15 degrees F

for high temp units, and 2-5 degrees F for lo-temp units.

Humidity Differential--The upper right cursor is flashing indicat-

ing the mode. If the flame shuts off because the humidity set point, the

humidity must rise above the ( Set Point plus Humidity Differential) for

the flame to come back on. (Normally set to 5%)

Multiple Heater Notes

When multiple heaters are con-

nected together, the temperature and

humidity sensors must be connected

to the master.

down arrow switches to alter the

hours. Setting range is 0 to 200

hours.

Drying Grain In The

Hours To Shutdown

Mode

While drying grain, depress and

hold the "SHUTDOWN HOURS"

switch. While holding in on that

switch, depress the "START"

switch. After depressing the start

switch one time, the heater is in the

shutdown mode. Then, the fan and

heater shutdown when the time ex-

pires. This is indicated by the lower

left cursor flashing.

Depressing the start switch

again (while holding in on the

"SHUTDOWN HOURS" switch)

will cause only the heater to shut off.

This leaves the fan on when the time

expires. This is indicated by the 2nd

from lower left cursor flashing. De-

pressing the start switch one more

time returns the heater into the con-

tinuous--non-shutdown mode.

Run Hours Display

Run hours are recorded when the

controller detects that the fan is on

(airflow). The hours may be viewed

by depressing the "HOURS" to get

hours and "HOURS X 1000" to get

the number of 1000 hours accumu-

lated.

Programming Hours To Shutdown

To change the hours to shutdown, depress and hold the "SHUTDOWN

HOURS" switch. While holding in on the switch, depress the up and

Setting the cycle set point.

OPERATING PROCEDURE