beautypg.com

Chapter 13 pneumatic fill kit assembly, Roof panel, Pneumatic fill kit assembly – Grain Systems Tanks PNEG-256 User Manual

Page 59

background image

PNEG-256 6', 7' & 9' Bulk Feed Tanks

59

13. PNEUMATIC FILL KIT ASSEMBLY

Roof Panel

Identical pre-punched roof panels are available from Manufacturer for inlet and outlet sections
of Pneumatic fill systems. Extruded lip of the panels provide for weather tight installation.
Caulking placed between angle rings virtually eliminates all leakage problems. Rubber seal must
be utilized at roof cap area to prevent material “Blow By” from pressurized systems.

To install fill kits in roof panels not pre-punched, cut 5 5/8" (143 mm) diameter holes in opposing
roof panels as shown. Caulk sufficiently to provide weather tight seal.

Refer to “Peak Ring Seal Strip” installation procedure when installing pneumatic fill kits.

Abnormal pressure may require us of optional “Cap Hold Down Package” (BLK-10474).

Note: Inlet and exhaust parts from roof eave upward supplied with kit.

Figure 13A

Fill tube is 4" in Diameter
(available)

5/16'' Square Neck Bolt

5/16'' Hex Nut
(S-396)

Exhaust Tube is 6" in
Diameter

Cupped Washers