Page 2 of 3 – Grain Systems PNEG-1590 User Manual
Page 2

Revision 08
Page 2 of 3
Dryer Pre-fire Checklist
___ Check wiring in control boxes (Jumpers, loose wires, and strands).
___
Check wiring to the main power supply.
___
Check location of 1FI and 2FI wires, make sure 1 is on L1 and 2 is on L3.
___
Capacitor is installed on moisture control light (2000 series only).
___
Check all overloads are set at the rated amperage listed on motors rating plate.
___
Check wiring in fan boxes
___
Check fan overloads are set at the rated amperage listed on the motors rating plate.
___
Check direction of flow on all solenoids and regulators.
___
Perform a Dielectric Strength (Hi-Pot) test in accordance with work instruction QSD-000152.R00. ___ Pass, ___ Fail
___
Perform a Grounding Continuity test in accordance with work instruction QSD-000151.R00. ___ Pass, ___ Fail
___
Apply required power.
___
Install newest version of software into the computer. Version #
_______
___
Check switch wiring using feature in program (Vision).
___
Check switch lights for correct colors.
___
Set dip switches on back of display I/O. 2 & 3 on for GSI, 2 on for FFI.
___
Put correct model number of dryer into computer.
___
Check LCD for backlighting.
___
Do all operating lights work?
___
Overload amp range: Load _______, Unload _______, Fan #1 _______, #2 _______, #3 _______, #4 _______, #5 _______, #6 _______.
___
Auxiliary overload amp range: Unload
_________ Load _________.
___
Check 12 volt output. _________ Volts.
___
Check that grain and plenum temperature read out is correct.
___
Check the SCR drive resistor for the proper size.
___
Check outside light.
___
Check motor rotation: Unload (CCW)
_________Load (CW) _________ Metering rolls (CW) _________ Load CCW for FF _________.
___
Ensure Aux contactor engages when load is on
___
Ensure Aux contactor engages when unload is on
___
Check Unload Auger for Excessive Vibration.
___
Metering roll RPM and BPH are displayed and counting.
___
Check 2 speed operation with moisture control on for low speed and off for high speed.
___
Turn pots on main I/O board fully to the right.
___
Set SCR board pots IR to 10 o’clock and CL to 4 o’clock.
___
Adjust minimum voltage for SCR drive to 9 volts @ 0 on pot display for vision set 9 volts @ 50 for (2000 series)
___
Adjust maximum voltage for SCR drive to 180 volts @ 1000 on pot display
___
Check for unload auger clean out time delay after SCR has shut off meter rolls.
___
Check load motor on and off operation with the mercury switch with delay.
___
Check the out of grain timer is working.
___
Check motor running amps: Unload
___________amps. Load _____________amps.
___
Run fans with airswitch on to make sure it is wired correctly.
___
Check the fan motor(s) running amps: Fan #1
_______ Fan #2 _______Fan #3 _______Fan #4 _______Fan #5 _______Fan #6 _______
___
Check total running amps of the dryer:
_______amps.
___
Is there a 5 second time delay between each fan start-up.
___
Check 20 second safety on burners with burner on but with no gas attached. #1
____ #2 ____ #3 ____ #4 ____ #5 ____ #6 _____
Dryer Burner Operation Checklist
___
Adjust the vaporizer coil (LP units only). Burner #1
______ #2 ______ #3 ______ #4 ______ #5 ______ #6______
___
Operate dryer in continuous flow mode.
___
Do all burners light: Burner #1
______ #2 ______ #3 ______ #4 ______ #5 ______ #6 ______
___
Adjust gas pressure
______ 3 & 10 lbs. for LP, ______ 2 & 6 lbs. for natural gas.
___
Check burner pipe trains for gas leaks: Burner #1
______ #2 ______ #3 ______ #4 ______ #5 ______ #6 ______
___
Do all burners cycle from high to low: Burner #1
______ #2 ______ #3 ______ #4 ______ #5 ______ #6 ______
___
Cycle burner six times by using the burner control switch
___
Cycle burner six times by setting the computer to on/off fire
___
Operate dryer in staged batch mode 2 times.
___
Does moisture control hold at the end of the dry cycle?
___
Video dryer with all motors and burners on.
___
Burn all gas out of pipe train.
Safety Shutdown Checklist
___
Housing high limit for fan #1
______ #2 ______ #3 ______ #4 ______ #5 ______ #6 ______
___
Vapor high limit for each fan (On LP units only) #1
______ #2 ______ #3 ______ #4 ______ #5 ______ #6 ______
___
Fixed grain high limits: Lower
____ Middle ____ Upper ____.
___
Check discharge switch with unload running to check discharge vibration and ensure proper shut down
___
Remove grain sensor wires to ensure proper wiring
___
Auxiliary user safety.
___
Plenum high limit for each plenum chamber.
___
Motor overload.
___
Make sure all covers are on boxes and housing high limits