Installation – Grain Systems Unload Augers PNEG-1556 User Manual
Page 32

3. Installation
32
PNEG-1556 8", 10" and 12" Commercial Vertical Drive Unit - Dual Drive
Horizontal Drive
Vertical Drive
A. A magnetic starter should be used for the operator’s protection and for the protection of the motor.
This is to protect the operator against accidental restart caused by power interruption, conductor
fault, low voltage, circuit interruption or motor overload. Therefore, the motor must be restarted
manually. If using a motor with built-in thermal overload protection, make sure this type of motor has
a manual reset.
Auger
Part #
Motor
Sheave
Size
Flight Sheave
NEMA Motor
Frame
Motor HP
Belt
Size
Belt
Quantity
Belt Type
Size
RPM
8''
CE-00566
3.5''
15''
409
182T and 184T 3-5 HP
56
2
B
GK1346
213T and 215T 7-1/2 - 10 HP
57
3
10''
MHC00743
3.75''
18.4"
357
184T
5 HP
65
2
BX
213T and 215T 7-1/2 - 10 HP
MHC00485
254T
15 HP
67
3
BX
12"
MHC00020
3.75''
18.4"
357
213T and 215T 7-1/2 - 10 HP
68
2
BX
MHC00486
254T and 256T 15-20 HP
70
3
Auger
Part #
Motor
Sheave
Size
Flight Sheave
NEMA Motor
Frame
Motor HP
Belt
Size
Belt
Quantity
Belt Type
Size
RPM
8''
GK1346
5.0''
15"
584
184T
5 HP
57
2
B
10''
GK4441
4.0''
15"
467
213T
7-1/2 HP
59
3
B
12''
MHC01253
3.5''
15"
409
215T
10 HP
62
3
BX
1750 RPM electric motors and controls shall be installed by a qualified
electrician and must meet the standards set by the National Electrical Code and
all local and state codes. Reset and motor starting controls shall be located
where the operator has unrestricted access to the controls.
Disconnect and lock out power before resetting motor overloads. Ensure
electric motors are grounded.