Gate Sensitivity
 
The Peak Atlas SCR attempts to trigger the device under test at eight discrete 
gate currents, in ascending order. 
 
Trigger test level 1
100
µA
Trigger test level 2
500
µA
Trigger test level 3
2.5mA
Trigger test level 4
10mA
Trigger test level 5
25mA
Trigger test level 6
50mA
Trigger test level 7
75mA
Trigger test level 8
90mA
 
Thus, for example, a reported trigger current of 10mA means that device 
triggering occurred at a gate current of 10mA, but not at 2.5mA. Therefore the 
trigger current for the device under test is between 2.5mA and 10mA. 
 
Although Triacs are tested in both quadrants 1 and 3, the reported gate trigger 
current (for both SCRs and Triacs) is that which applies to quadrant 3. 
First test 
 
 
 
 
 
 
Last test
- PS1502A (6 pages)
 - VMB6PBN (15 pages)
 - VTTEST14 (5 pages)
 - VMB3PS (10 pages)
 - PSSE60 (18 pages)
 - VMB8IR (10 pages)
 - PSSE24 (4 pages)
 - VMBLCDWB (12 pages)
 - VMB1TSW (24 pages)
 - VL3288 (5 pages)
 - PSSMV24 (23 pages)
 - VMB4IRT (16 pages)
 - VMB7IN (8 pages)
 - VMB1USB (6 pages)
 - PSI600B (29 pages)
 - VL06LA (4 pages)
 - PSSEUSB6A (2 pages)
 - PS603 (17 pages)
 - VMB1TS (43 pages)
 - PSSE23 (4 pages)
 - VL1212 (29 pages)
 - VL7168 (7 pages)
 - PSSE45 (19 pages)
 - PS925 (13 pages)
 - VMB1BL (12 pages)
 - VMB1RS (6 pages)
 - PSS1320 (11 pages)
 - PSSMV8 (20 pages)
 - VMB8PB (16 pages)
 - VMB4RF (8 pages)
 - VMBRSUSB (8 pages)
 - PI300BN (33 pages)
 - VMBGPTCx (12 pages)
 - PSC1350 (2 pages)
 - VTTEST15 (7 pages)
 - PSSEUSB4 (2 pages)
 - VMB4DC (18 pages)
 - VMBGP1x (12 pages)
 - PSSMV2 (4 pages)
 - VMB8PBU (12 pages)
 - PSIC75B (18 pages)
 - PS12015 (5 pages)
 - VMB4TX (1 page)
 - VL6278 (12 pages)
 - VMB4PD (35 pages)
 