Minimum and maximum temperature
The sensor records the minimum and maximum temperature.
These values can be examined or reset via the temperature controller (VMB1TC / VMB1TCW) or through the Velbus
link software via a PC connected to the Velbus PC interface (VMB1USB, VMB1RS of VMBRSUSB).
Differential thermostat
Using two sensors a differential thermostat can be created. When the difference in temperature between both sensors
reaches a certain value, the relay channel can be activated.
To achieve this, the first sensors must know the address of the second one. The second sensor must than be linked
to a relay channel. The temperature difference value is set on the first sensor.
Factory settings
After receiving this module, following factory default settings are already stored into the sensor:
Description
Factory default
Zone number
No zone
Differential sensor address
None
Operating mode
Heating
Unjam heating valve
Disabled
Unjam heating valve circulation pump
Disabled
Desired comfort temperature for heating
22°C
Desired day temperature for heating
20°C
Desired night temperature for heating
15°C
Anti-freeze safeguard
5°C
Heating limit
30°C
Temperature difference (fast heating/cooling or differential thermostat)
3°C
Calibration factor
-2.5°C
Hysteresis
0.5°C
Desired comfort temperature for cooling
21°C
Desired day temperature for cooling
23°C
Desired night temperature for cooling
26°C
Lower limit cooling preset range
16°C
Upper limit cooling preset range
36°C
Low temperature alarm
3°C
High temperature alarm
30°C
Default duration temporary mode (sleep timer)
1 hour
Time interval for automatic transmission temperature
Disabled
Local control
Unlocked
Cycling protection delay
1 minute