Vishay high power products, Phase control thyristors (stud version), 180 a – C&H Technology 181RKI...PbF Series User Manual
Page 4
Document Number: 94382
For technical questions, contact: [email protected]
www.vishay.com
Revision: 30-Apr-08
3
180RKI...PbF /181RKI...PbF Series
Phase Control Thyristors
(Stud Version), 180 A
Vishay High Power Products
Note
• The table above shows the increment of thermal resistance R
thJC
when devices operate at different conduction angles than DC
TRIGGERING
PARAMETER SYMBOL
TEST
CONDITIONS
VALUES
UNITS
TYP.
MAX.
Maximum peak gate power
P
GM
T
J
= T
J
maximum, t
p
≤ 5 ms
10
W
Maximum average gate power
P
G(AV)
T
J
= T
J
maximum, f = 50 Hz, d% = 50
2.0
Maximum peak positive gate current
I
GM
T
J
= T
J
maximum, t
p
≤ 5 ms
3.0
A
Maximum peak positive gate voltage
+ V
GM
20
V
Maximum peak negative gate voltage
- V
GM
5.0
DC gate current required to trigger
I
GT
T
J
= - 40 °C
Maximum required gate trigger/
current/voltage are the lowest
value which will trigger all units
12 V anode to cathode applied
130
-
mA
T
J
= 25 °C
65
150
T
J
= 125 °C
35
-
DC gate voltage required to trigger
V
GT
T
J
= - 40 °C
2.0
-
V
T
J
= 25 °C
1.2
2.5
T
J
= 125 °C
0.9
-
DC gate current not to trigger
I
GD
T
J
= T
J
maximum
Maximum gate current/voltage not
to trigger is the maximum value
which will not trigger any unit with
rated V
DRM
anode to cathode
applied
10
mA
DC gate voltage not to trigger
V
GD
0.25
V
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL
TEST
CONDITIONS
VALUES
UNITS
Maximum operating junction
temperature range
T
J
- 40 to 125
°C
Maximum storage temperature range
T
Stg
- 40 to 150
Maximum thermal resistance,
junction to case
R
thJC
DC operation
0.15
K/W
Maximum thermal resistance,
junction to ambient
R
thCS
Mounting surface, smooth, flat and greased
0.04
Mounting force, ± 10 %
Non-lubricated threads
31
(275)
Nm
(lbf · in)
Lubricated threads
24.5
(210)
Approximate weight
280
g
Case style
See dimensions - link at the end of datasheet
TO-209AB (TO-93)
ΔR
thJC
CONDUCTION
CONDUCTION ANGLE
SINUSOIDAL CONDUCTION
RECTANGULAR CONDUCTION
TEST CONDITIONS
UNITS
180°
0.050
0.032
T
J
= T
J
maximum
K/W
120°
0.063
0.059
90°
0.080
0.082
60°
0.118
0.124
30°
0.225
0.228