300hf..l series, Vishay high power products, Standard recovery diodes (stud version), 300 a – C&H Technology 300HF..L Series User Manual
Page 3

www.vishay.com
For technical questions, contact: [email protected]
Document Number: 93507
2
Revision: 02-Jun-08
300HF..L Series
Vishay High Power Products
Standard Recovery Diodes
(Stud Version), 300 A
FORWARD CONDUCTION
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
Maximum average forward current
at case temperature
I
F(AV)
180° conduction, half sine wave
300
A
120
°C
Maximum peak, one cycle forward,
non-repetitive surge current
I
FSM
t = 10 ms
No voltage
reapplied
Sinusoidal half wave,
initial T
J
= T
J
maximum
5700
A
t = 8.3 ms
5900
t = 10 ms
100 % V
RRM
reapplied
4800
t = 8.3 ms
5000
Maximum I
2
t for fusing
I
2
t
t = 10 ms
No voltage
reapplied
160
kA
2
s
t = 8.3 ms
148
t = 10 ms
100 % V
RRM
reapplied
115
t = 8.3 ms
105
Maximum I
2
√t for fusing
I
2
√t
t = 0.1 to 10 ms, no voltage reapplied
1600
kA
2
√s
Maximum value of threshold voltage
V
F(TO)
T
J
= 180 °C
0.70
V
Maximum value of forward
slope resistance
r
f1
0.40
m
Ω
Maximum forward voltage drop
V
FM
I
pk
= 942 A, T
J
= 25 °C
1.14
V
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL
TEST
CONDITIONS
VALUES
UNITS
Maximum junction operating and
storage temperature range
T
J
, T
Stg
- 40 to 180
°C
Maximum thermal resistance,
junction to case
R
thJC
DC operation
0.17
K/W
Maximum thermal resistance,
case to heatsink
R
thCS
Mounting surface, smooth, flat and greased
0.08
Maximum allowed mounting torque
+ 0 - 20 %
Not lubricated threads
37
N · m
lubricated threads
28
Approximate weight
250
g
Case style
See dimensions - link at the end of datasheet
DO-205AB (DO-9)