C&H Technology PS21962-4S User Manual
Page 5
PS21962-4S
Intellimod™ Module
Dual-In-Line Intelligent Power Module
5 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
4
Rev.12/09
Thermal Characteristics
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Junction to Case
R
th(j-c)Q
Inverter IGBT (Per 1/6 Module)
—
—
4.7
°C/Watt
R
th(j-c)D
Inverter FWDi (Per 1/6 Module)
—
—
5.4
°C/Watt
Recommended Conditions for Use
Characteristic
Symbol
Condition
Min.
Typ.
Value
Units
Supply Voltage
V
CC
Applied between P-N Terminals
0
300
400
Volts
Control Supply Voltage
V
D
Applied between V
P1
-V
NC
, V
N1
-V
NC
13.5
15.0
16.5
Volts
V
DB
Applied between V
UFB
-U,
13.0
15.0
18.5
Volts
V
VFB
-V, V
WFB
-W
Control Supply Variation
dV
D
, dV
DB
-1
—
1
V/µs
Arm Shoot-through Blocking Time
t
DEAD
For Each Input Signal, T
C
≤ 100°C
1.5
—
—
µs
Allowable Minimum Input
P
WIN(on)
0.5
—
—
µs
Pulse Width*
P
WIN(off)
0.5
—
—
µs
V
NC
Voltage Variation
V
NC
Between V
NC
-N (Including Surge)
-5.0
—
5.0
Volts
*DIP-IPM might not make response or work properly if the input signal pulse width is less than the recommended minimum value.