beautypg.com

C&H Technology PS21962-4S User Manual

Page 10

background image

PS21962-4S
Intellimod™ Module
Dual-In-Line Intelligent Power Module
5 Amperes/600 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272

9

Rev. 12/09

10

0

10

1

10

2

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIME, t

on

, (ns)

SWITCHING TIME (ON) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART N-SIDE)

10

3

10

4

10

0

10

1

10

2

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIME, t

on

, (ns)

SWITCHING TIME (ON) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART P-SIDE)

10

3

10

4

10

0

10

1

10

2

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIME, t

off

, (ns)

SWITCHING TIME (OFF) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART P-SIDE)

10

3

10

4

10

0

10

1

10

1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIME, t

c(on)

, (ns)

SWITCHING TIME (ON) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART N-SIDE)

10

2

10

3

10

0

10

1

10

1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIME, t

c(off)

, (ns)

SWITCHING TIME (OFF) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART N-SIDE)

10

2

10

3

10

0

10

1

10

2

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIME, t

off

, (ns)

SWITCHING TIME (OFF) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART N-SIDE)

10

3

10

4

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= V

DB

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= V

DB

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING LOSS, P

SW(off)

, (mJ/PULSE)

10

1

SWITCHING LOSS (OFF) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART N-SIDE)

10

0

10

-1

10

-2

10

0

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING LOSS, P

SW(on)

, (mJ/PULSE)

10

1

SWITCHING LOSS (ON) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART P-SIDE)

10

0

10

-1

10

-2

10

0

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING LOSS, P

SW(off)

, (mJ/PULSE)

10

1

SWITCHING LOSS (OFF) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART P-SIDE)

10

0

10

-1

10

-2

10

0

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= V

DB

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= V

DB

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

V

CC

= 300V

V

CIN

= 0 ⇔ 5V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD