beautypg.com

VEGA VEGAPULS 61 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA__HART four-wire User Manual

Page 54

background image

30 mm (1.180 in)

15 mm (0.590 in)

0

-15 mm (- 0.590 in)

- 30 mm (- 1.180 in)

1,0 m (3.280 ft)

10 m (32.80 ft)

Fig. 32: Deviation VEGAPULS 61 with plastic horn antenna and increased sensitivity

Influence of the ambient temperature to the sensor electronics

8

)

A

verage temperature coefficient of the zero

signal (temperature error)

0.03 %/10 K

Ambient conditions

A

mbient, storage and transport temperature

-40 … +70 °C (-40 … +158 °F)

Process conditions

V

essel pressure

-

E

ncapsulated antenna system

-100 … 300

kPa/-1 … 3 bar (-14.5 … 43.5 psi)

-

P

lastic horn antenna

-100 … 200

kPa/-1 … 2 bar (-14.5 … 29.0 psig)

P

rocess temperature (measured on the

process fitting)

-40 … +80 °C (-40 … +176 °F)

V

ibration resistance

9)

-

E

ncapsulated antenna system

mechanical vibrations up to 4 g in the frequency
range 5 … 200 Hz

-

P

lastic horn antenna with compression

or adapter flange

mechanical vibrations up to 2 g in the frequency
range 5 … 200 Hz

-

P

lastic horn antenna with mounting strap

mechanical vibrations up to 1 g in the frequency
range 5 … 200 Hz

Electromechanical data - version IP 66/IP 67

C

able entry

-

D

ouble chamber housing

l

1

x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),

1

x blind stopper M20 x 1.5; plug M12 x 1 for

VEGADIS

61 (

optional)

or:

8)

R

elating to the nominal measuring range, in the temperature range

-40 … +80 °C .

9)

T

ested according to the guidelines of German Lloyd, GL directive 2.

54

VEGAPULS

61 • 4 … 20

mA/HART four-wire

10 S

upplement

28439

-EN

-100426