beautypg.com

VEGA VEGAPULS 61 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA__HART four-wire User Manual

Page 20

background image

max.

min.

2

1

Fig. 15: Pipe antenna system in a tank. The vent hole in the surge pipe must be
in one plane with the polarisation marking on the sensor.

1

Marking of the polarisation direction

2

Vent hole max. ø 5 mm (0.2 in)

I

f possible, the antenna diameter of the sensor should correspond to

the inner diameter of the tube. With VEGAPULS 61 this is approx.
40

mm (1.575 in). The sensor can be used with tube diameters

between 40 … 80 mm (1.575 … 3.15 in).

Bypass tube
A

s an alternative to the surge pipe in the vessel, a tube system outside

of the vessel is possible as a bypass tube. Select during setup the
function "Bypass tube".

A

lign the sensor in such a way that the polarisation marking on the

process fitting is in the same plane as the tube holes or the tube
connection openings (see illustration: "VEGAPULS in a bypass tube").

20

VEGAPULS

61 • 4 … 20

mA/HART four-wire

4 M

ounting

28439

-EN

-100426