11 Supplement

VEGAPULS 66 • HART and accumulator pack

40933-EN-121011

Seal

Antenna impedance

cone

Process temperature (measured on the process

fitting)

FKM (Viton)

PFFE

-40 … +150 °C (-40 … +302 °F)

FFKM (Kalrez 6375)

PFFE

-20 … +150 °C (-4 … +302 °F)

FPM Viton covered (FDA

approved)

PFFE

-40 … +150 °C (-40 … +302 °F)

EPDM (FDA approved)

PFFE

-40 … +150 °C (-40 … +302 °F)

Graphite

Ceramic

-110 … +250 °C (-166 … +482 °F)

Ceramic

-200 … +400 °C (-328 … +752 °F)

Vessel pressure relating to the antenna cone

Ʋ PTFE

-1 … 40 bar (-100 … 4000 kPa/-14.5 … 580 psi) with

PN 40

Ʋ Ceramic

-1 … 160 bar (-100 … 16000 kPa/-14.5 … 2321 psi) with

PN 160

Vessel pressure relating to the flange

nominal stage

see supplementary instructions manual "Flanges ac-

cording to DIN-EN-ASME-JIS"

Vibration resistance

4 g at 5 … 200 Hz according to EN60068-2-6 (vibration

with resonance)

Shock resistance

100 g, 6 ms according to EN 60068-2-27 (mechanical

shock)

Data on rinsing air connection
Pressure max.

6 bar (87.02 psi)

Air flow without reflux valve

Ʋ 0.1 bar (1.45 psi)

4.2 m

3

/h

Ʋ 1.2 bar (7.25 psi)

10.2 m

3

/h

Air flow with reflux valve

Ʋ 0.2 bar (2.9 psi)

2.0 m

3

/h

Ʋ 0.55 bar (7.98 psi)

4.2 m

3

/h

Ʋ 1.2 bar (17.4 psi)

7.2 m

3

/h

Thread

G¼ A

Closure

Ʋ with non-Ex

Dust protection cover of PE

Ʋ with Ex

Threaded plug of 316Ti

2 reflux valves - enclosed unassembled (with non-Ex optional, with Ex included in the scope of

delivery)

Ʋ Material

316Ti

Ʋ Seal

FKM (Viton), FFKM (Kalrez 6375)

Ʋ for tube diameter

10 mm

Ʋ opening pressure

0.5 bar (7.252 psi)

Ʋ Nominal pressure stage

PN 250