11 Supplement
VEGAPULS 66 • HART and accumulator pack
40933-EN-121011
11 Supplement
11.1 Technical data
General data
316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
Ʋ Process fitting
316L, Hastelloy C22 plated, PP
Ʋ Process seal
On site
Ʋ Antenna
316L, Hastelloy C22
Ʋ Antenna impedance cone
PTFE, ceramic (99.7 % AL
2
O
3
)
Ʋ seal, antenna system
FKM (A+P GLT FPM 70.16-06), FFKM (Kalrez 6375),
silicone FEP coated (A+P FEP-O-SEAL), EPDM
(A+P 75.5/KW75F), PTFE, graphite (99.9 %) and
ceramic
Materials, non-wetted parts
Ʋ Plastic housing
plastic PBT (Polyester)
Ʋ Aluminium die-casting housing
Aluminium die-casting AlSi10Mg, powder-coated - basis:
Polyester
Ʋ Stainless steel housing
316L
Ʋ Seal between housing and housing
cover
NBR (stainless steel housing, precision casting), silicone
(aluminium/plastic housing; stainless steel housng,
electropolished)
Ʋ Inspection window in housing cover
(optional)
Polycarbonate
Ʋ Ground terminal
316L
Ohmic contact
Between ground terminal, process fitting and antenna
Process fitting
Flanges DIN from DN 50, ANSI from 2"
Weight (depending on housing, process
fitting and antenna)
approx. 6.3 … 136 kg (13.89 … 299.8 lbs)
Antenna extension
1.9 kg/m (1.374 lbs/ft)
Torque for NPT cable glands and Conduit tubes
Ʋ Plastic housing
max. 10 Nm (7.376 lbf ft)
Ʋ Aluminium/Stainless steel housing
max. 50 Nm (36.88 lbf ft)
Input variable
Measured variable
The measured quantity is the distance between process
fitting of the sensor and product surface. The reference
plane is the seal surface on the hexagon or the lower
side of the flange.