3 Product description

VEGAPULS 66 • HART and accumulator pack

40933-EN-121011

The scope of delivery encompasses:

Radar sensor with integrated accumulator

Battery charger

Documentation

– this operating instructions manual

– Test certificate measuring accuracy (optional)

– Operating instructions manual "Indicating and adjustment

module" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The VEGAPULS 66 is a radar sensor for continuous level measure-

ment of liquids under difficult process conditions. It is suitable for

applications in storage tanks, process vessels or standpipes. The

instrument can be used universally thanks to the different antenna

versions.
The version with horn antenna is particularly suitable for the meas-

urement of liquids and bulk solids under extremely difficult process

conditions such as buildup, condensation and foam generation as

well as strong product movement.
With the version without antenna, the antenna system is formed in

conjunction with a measuring tube (surge or bypass tube). This ver-

sion is particularly suitable for measurement of solvents and liquid

gases.
The instrument can be used with products with an ε

r

value ≥1.8. The

actually achievable value depends on the measuring conditions, the

antenna system, the standpipe or bypass.

The antenna of the radar sensor emits short radar pulses with a

duration of approx. 1 ns. These pulses are reflected by the product

and received by the antenna as echoes. The transit time of the radar

pulses from emission to reception is proportional to the distance and

hence to the level. The determined level is converted into an appropri-

ate output signal and outputted as measured value.

The instrument is powered via an integrated accumulator. This allows

operation of the instrument independently of the mains or a control

system. To achieve a longer battery lifetime, the instrument is preset

to HART multidrop. This puts a load of only 4 mA current on the ac-

cumulator.

3.3 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

according to DIN EN 24180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.