VEGA VEGAPULS SR 68 HART and accumulator pack User Manual
Page 65
65
11 Supplement
VEGAPULS SR 68 • HART and accumulator pack
40934-EN-130624
1,0 m (3.28 ft)
10 mm (0.394 in)
2 mm (0.079 in)
- 2 mm (- 0.079 in)
- 10 mm (- 0.394 in)
0
1 2
3
Fig. 48: Deviation under reference conditions
1 Reference plane
2 Antenna edge
3 Recommended measuring range
Repeatability
≤ ±1 mm
Deviation with bulk solids
The values depend to a great extent on the application.
Binding specifications are thus not possible.
Deviation under EMC influence
≤ ±30 mm
Variables influencing measurement accuracy
Specifications apply to the digital measured value
Temperature drift - Digital output
±3 mm/10 K relating to the max. measuring range or
max. 10 mm
Additional deviation through electromag-
netic interference acc. to EN 61326
< ±50 mm
Specifications apply also to the current output
Temperature drift - Current output
±0.03 %/10 K relating to the 16 mA span max. ±0.3 %
Deviation on the current output through
analogue/digital conversion
< ±15 µA
Deviation on the current output due to
strong, high frequency electromagnetic
fields acc. to EN 61326
< ±150 µA
Characteristics and performance data
Measuring frequency
K-band (26 GHz technology)
Measuring cycle time approx.
700 ms
Step response time
1)
≤ 3 s
Beam angle
2)
Ʋ Horn antenna ø 40 mm (1.575 in)
20°
Ʋ Horn antenna ø 48 mm (1.89 in)
15°
Ʋ Horn antenna ø 75 mm (2.953 in)
10°
1)
Time span after a sudden measuring distance change by max. 0.5 m in liquid applications, max 2 m with bulk
solids applications, until the output signal has taken for the first time 90 % of the final value (IEC 61298-2).
2)
Outside the specified beam angle, the energy of the radar signal has a level which is reduced by 50 % (-3 dB)