7 Setup with PACTware

WEIGHTRAC 31 • Foundation Fieldbus

42375-EN-131120

Fig. 31: Set up totalizer

With this function you can activate the totalizer. As a default setting,

the totalizer is deactivated.
You can set material quantity that causes a counting pulse to be

outputted via the digital output (NPN transistor).
The leak volume suppression determines which degree of filling (in

percent) activates the totalizer.
With this you can avoid a continued summation of contamination or

slight buildup on an otherwise empty conveyor belt.

In a last step, complete the adjustment with the setup assistant. After

terminating the assistant, the program jumps back to the usual DTM

program environment.
Information:

After a successful run of the setup assistant, you have to adjust two

points in the DTM.

Setup - Totalizer (step 10)

Complete