VEGA VEGABAR 81 HART and accumulator pack - Operating Instructions User Manual
Page 51
51
11 Supplement
VEGABAR 81 • HART and accumulator pack
45026-EN-131107
Adjustment range of the zero/span adjustment relating to the nominal measuring range:
Ʋ zero
-20 … +95 %
Ʋ span
-120 … +120 %
1)
Ʋ Difference between zero and span
max. 120 % of the nominal range
Recommended max. turn down
20 : 1 (no limitation)
Nominal measuring ranges and overload capability in bar/kPa
The specifications are only an overview and refer to the measuring cell. Limitations due to the
material and version of the process fitting as well as the selected pressure type are possible. The
specifications on the nameplate apply.
Nominal range
Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
Gauge pressure
0 … +0.4 bar/0 … +40 kPa
+2 bar/+200 kPa
-1 bar/-100 kPa
0 … +1 bar/0 … +100 kPa
+5 bar/+500 kPa
-1 bar/-100 kPa
0 … +2.5 bar/0 … +250 kPa
+10 bar/+1000 kPa
-1 bar/-100 kPa
0 … +10 bar/0 … +1000 kPa
+35 bar/+3500 kPa
-1 bar/-100 kPa
0 … +25 bar/0 … +2500 kPa
+50 bar/+5000 kPa
-1 bar/-100 kPa
0 … +40 bar/0 … +4000 kPa
+80 bar/+8000 kPa
-1 bar/-100 kPa
0 … +100 bar/0 … +10 MPa
+200 bar/+20 MPa
-1 bar/-100 kPa
0 … +250 bar/0 … +25 MPa
+500 bar/+50 MPa
-1 bar/-100 kPa
0 … +600 bar/0 … +60 kPa
+1200 bar/+120 MPa
-1 bar/-100 kPa
0 … +1000 bar/0 … +100 MPa
+1500 bar/+150 MPa
-1 bar/-100 kPa
-1 … 0 bar/-100 … 0 kPa
+5 bar/+500 kPa
-1 bar/-100 kPa
-1 … +1.5 bar/-100 … +150 kPa
+10 bar/+1000 kPa
-1 bar/-100 kPa
-1 … +10 bar/-100 … +1000 kPa
+80 bar/+8000 kPa
-1 bar/-100 kPa
-1 … +25 bar/-100 … +2500 kPa
+80 bar/+8000 kPa
-1 bar/-100 kPa
-1 … +40 bar/-100 … +4000 kPa
+80 bar/+8000 kPa
-1 bar/-100 kPa
-0.2 … +0.2 bar/-20 … +20 kPa
+2 bar/+200 kPa
-1 bar/-100 kPa
-0.5 … +0.5 bar/-50 … +50 kPa
+5 bar/+500 kPa
-1 bar/-100 kPa
Absolute pressure
0 … 1 bar/0 … 100 kPa
5 bar/+500 kPa
0 bar abs.
0 … 2.5 bar/0 … 250 kPa
10 bar/+1000 kPa
0 bar abs.
0 … 10 bar/0 … 1000 kPa
35 bar/+3500 kPa
0 bar abs.
0 … 25 bar/0 … 2500 kPa
50 bar/+5000 kPa
0 bar abs.
0 … 40 bar/0 … 4000 kPa
80 bar/8000 kPa
0 bar abs.
Nominal measuring ranges and overload capacity in psi
1)
Values less than -1 bar cannot be set.