11 Supplement

VEGABAR 86 • Profibus PA

45042-EN-131107

Connection cable with IP 68 (1 bar)

version

PE

Connection cable, master and slave

sensor

PE, PUR

Weights
Basic weight

0.7 kg (1.543 lbs)

Suspension cable

0.1 kg/m (0.07 lbs/ft)

Connection tube

1.5 kg/m (1 lbs/ft)

Straining clamp

0.2 kg (0.441 lbs)

Unassembled screw connection

0.4 kg (0.882 lbs)

Input variable
Adjustment
Adjustment range of the min./max. adjustment relating to the nominal measuring range:

Ʋ Percentage value

-10 … 110 %

Ʋ Pressure value

-20 … 120 %

Adjustment range of the zero/span adjustment relating to the nominal measuring range:

Ʋ zero

-20 … +95 %

Ʋ span

-120 … +120 %

1)

Ʋ Difference between zero and span

max. 120 % of the nominal range

Recommended max. turn down

20 : 1 (no limitation)

Nominal measuring ranges and overload capability in bar/kPa
The specifications are only an overview and refer to the measuring cell. Limitations due to the

material and version of the process fitting as well as the selected pressure type are possible. The

specifications on the nameplate apply.

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

Gauge pressure
0 … +0.025 bar/0 … +2.5 kPa

+5 bar/+500 kPa

-0.05 bar/-5 kPa

0 … +0.1 bar/0 … +10 kPa

+15 bar/+1500 kPa

-0.2 bar/-20 kPa

0 … +0.4 bar/0 … +40 kPa

+30 bar/+3000 kPa

-0.8 bar/-80 kPa

0 … +1 bar/0 … +100 kPa

+35 bar/+3500 kPa

-1 bar/-100 kPa

0 … +2.5 bar/0 … +250 kPa

+50 bar/+5000 kPa

-1 bar/-100 kPa

0 … +10 bar/0 … +1000 kPa

+90 bar/+9000 kPa

-1 bar/-100 kPa

0 … +25 bar/0 … +2500 kPa

+130 bar/+13000 kPa

-1 bar/-100 kPa

Absolute pressure
0 … 0.1 bar/0 … 10 kPa

15 bar/1500 kPa

0.8 bar abs.

0 … 1 bar/0 … 100 kPa

35 bar/3500 kPa

0 bar abs.

0 … 2.5 bar/0 … 250 kPa

50 bar/5000 kPa

0 bar abs.

0 … 10 bar/0 … 1000 kPa

90 bar/9000 kPa

0 bar abs.

1)