2 supplementary information foundation fieldbus – VEGA VEGAFLEX 81 Foundation Fieldbus Coax probe User Manual
Page 75
75
11 Supplement
VEGAFLEX 81 • Foundation Fieldbus
44215-EN-130910
Ʋ EEx-ia instrument - Power supply
FISCO model
9 … 17.5 V DC
Ʋ EEx-ia instrument - Power supply
ENTITY model
9 … 24 V DC
Ʋ EEx-d instrument
14 … 32 V DC
Power supply by/max. number of sensors
Ʋ Fieldbus
max. 32 (max. 10 with Ex)
Electrical protective measures
Protection, depending on housing version
Ʋ Plastic housing
IP 66/IP 67
Ʋ Aluminium housing, stainless steel
housing - investment casting, stain-
less steel housing - electro-polished
IP 66/IP 68 (0.2 bar)
6)
Ʋ Aluminium and stainless housing, in-
vestment casting (optionally available)
IP 66/IP 68 (1 bar)
Overvoltage category
III
Protection class
III
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments must be carefully noted.
They are part of the delivery or can be do
w
11.2 Supplementary information Foundation Fieldbus
The following table gives you an overview of the instrument versions and the corresponding device
descriptions, the electrical characteristics of the bus system as well as the applied function blocks.
Revisions Data
DD-Revision
Rev_01
CFF-File
010101.cff
Device Revision
0101.ffo
0101.sym
Cff-Revision
xx xx 01
Device software revision
> 4.4.0
ITK (Interoperability Test Kit) Number
5.0.2
6)
The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting.